Bit field:
Bit
Signal name
00
Enable alarm A07903
01
Load monitoring only in the 1st quadrants
15
Automatic parameterization carried out
(p0340 = 1, p3900 > 0)
Dependency:
Refer to: r2197
Refer to: A07903
Note:
Re bit 00:
Alarm A07903 is output when the bit is set with p2197.7 = 0 (n_set <> n_act).
Re bit 01:
When the bit is set, the load monitoring is only carried out in the 1st quadrant as a result of the positive characteris-
tic parameters (p2182 ... p2190).
Re bit 15:
The bit indicates as to whether the automatic parameterization (p0340 = 1, p3900 > 0) for the parameters of the
extended monitoring functions was carried out. If the bit is not set, e.g. when activating the configuration (refer to
p0108.15), the parameterization is automatically carried out when booting even if r3925.0 is already 1.
p2149[0...n]
Monitoring configuration / Monit config
VECTOR
Can be changed: U, T
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Configuration word for signals and monitoring functions.
Bit field:
Bit
Signal name
00
Enable alarm A07903
01
Load monitoring only in the 1st quadrants
15
Automatic parameterization carried out
(p0340 = 1, p3900 > 0)
Dependency:
Refer to: r2197
Refer to: A07903
Note:
Re bit 00:
Alarm A07903 is output when the bit is set with p2197.7 = 0 (n_set <> n_act).
Re bit 01:
When the bit is set, the load monitoring is only carried out in the 1st quadrant as a result of the positive characteris-
tic parameters (p2182 ... p2190).
Re bit 15:
The bit indicates as to whether the automatic parameterization (p0340 = 1, p3900 > 0) for the parameters of the
extended monitoring functions was carried out. If the bit is not set, e.g. when activating the configuration (refer to
p0108.15), the parameterization is automatically carried out when booting even if r3925.0 is already 1.
p2150[0...n]
Hysteresis speed 3 / n_hysteresis 3
SERVO, VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Messages
Not for motor type: -
Min
0.00 [RPM]
Description:
Sets the hysteresis speed (bandwidth) for the following signals:
"|n_act| < speed threshold value 3" (BO: r2199.0)
"n_set >= 0" (BO: r2198.5)
"n_act >= 0" (BO: r2197.3)
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
1 signal
Yes
Yes
Yes
Calculated: -
Dynamic index: DDS, p0180
Units group: -
Max
-
1 signal
Yes
Yes
Yes
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: 3_1
Max
300.00 [RPM]
Parameters
List of parameters
0 signal
FP
No
8010
No
8010
No
-
Access level: 3
Func. diagram: 8010
Unit selection: -
Expert list: 1
Factory setting
0001 bin
0 signal
FP
No
8010
No
8010
No
-
Access level: 3
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
2.00 [RPM]
1-587