hit counter script

Siemens SINAMICS S Series List Manual page 147

Hide thumbs Also See for SINAMICS S Series:
Table of Contents

Advertisement

r0331[0...n]
Motor magnetizing current/short-circuit current actual / Mot I_mag_ratedAct
SERVO, VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Not for motor type: REL, FEM
Min
- [Arms]
Description:
Induction motor:
Displays the rated magnetizing current from p0320.
For p0320 = 0, the internally calculated magnetizing current is displayed.
Synchronous motor:
Displays the rated shirt-circuit current from p0320.
Dependency:
If p0320 was not entered, then the parameter is calculated from the rating plate parameters.
r0332[0...n]
Rated motor power factor / Mot cos_phi_rated
SERVO, VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Not for motor type: PEM, REL
Min
-
Description:
Displays the rated power factor for induction motors.
For IEC motors, the following applies (p0100 = 0):
For p0308 = 0, the internally-calculated power factor is displayed.
For p0308 > 0, this value is displayed.
For NEMA motors, the following applies (p0100 = 1):
For p0309 = 0, the internally-calculated power factor is displayed.
For p0309 > 0, this value is converted into the power factor and displayed.
Dependency:
If p0308 is not entered, the parameter is calculated from the rating plate parameters.
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0333[0...n]
Rated motor torque / Mot M_rated
SERVO, VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Not for motor type: -
Min
- [Nm]
Description:
Displays the rated motor torque.
Note:
For induction and reluctance motors, r0333 is calculated from p0307 and p0311.
For synchronous motors, r0333 is calculated from p0305, p0316, p0327 and p0328. The result can deviate from the
input in p0312. If p0316 = 0, then r0333 = p0312 is displayed.
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Max
- [Arms]
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Max
-
Calculated: -
Dynamic index: MDS, p0130
Units group: 7_4
Max
- [Nm]
Parameters
List of parameters
Access level: 3
Func. diagram: 5722, 6722,
6724
Unit selection: -
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
- [Nm]
1-147

Advertisement

Table of Contents
loading

Table of Contents