Parameters
List of parameters
Caution:
After booting or after a data set changeover, under certain circumstances, the new value is only available at BICO
sinks - that are interconnected to BICO source CO:r0479 - only after several 100ms as the connections must be
updated in the background (contrary to other BICO sources, e.g. CO:r0482).
The value is immediately available when non-cyclically reading r0479 (e.g. via the expert list).
r0479
CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
TM41
Can be changed: -
Data type: Integer32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the encoder actual position value Gn_XIST1 according to PROFIdrive for diagnostics. In contrast to
p0482, the value is updated in each DRIVE-CLiQ basic clock cycle and displayed with sign.
p0480[0...2]
CI: Signal source for encoder control word Gn_STW / Enc S_src Gn_STW
SERVO, VECTOR
Can be changed: T
Data type: Unsigned32 / Integer16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Sets the signal source for the encoder control word Gn_STW according to PROFIdrive.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Note:
When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished:
CI: p0480[0] = r2520[0], CI: p0480[1] = r2520[1] and CI: p0480[2] = r2520[2]
r0481[0...2]
CO: Encoder status word Gn_ZSW / Enc Gn_ZSW
SERVO, VECTOR
Can be changed: -
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the encoder status word Gn_ZSW according to PROFIdrive.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Bit field:
Bit
Signal name
00
Function 1 active
01
Function 2 active
02
Function 3 active
03
Function 4 active
04
Value 1
05
Value 2
06
Value 3
07
Value 4
08
Measuring probe 1 deflected
09
Measuring probe 2 deflected
11
Encoder fault acknowledge active
1-190
Calculated: -
Dynamic index: -
Units group: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Displayed in r0483
Displayed in r0483
Displayed in r0483
Displayed in r0483
Yes
Yes
Yes
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 3
Func. diagram: 9674
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 1580, 4720
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 4010, 4704,
4730
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
-
No
-
No
-
No
-
Does not exist
-
Does not exist
-
Does not exist
-
Does not exist
-
No
-
No
-
No
-