p3831[0...n]
Friction characteristic, value F1 / Friction F1
SERVO (Lin)
Can be changed: T
Data type: Floating Point
P-Group: Functions
Not for motor type: REL
Min
-1000000.00 [N]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 2nd value pair of the friction characteristic.
Dependency:
Refer to: p3821, p3845
p3832[0...n]
Friction characteristic, value M2 / Friction M2
SERVO, VECTOR
Can be changed: T
(n/M)
Data type: Floating Point
P-Group: Functions
Not for motor type: REL
Min
-1000000.00 [Nm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 3rd value pair of the friction characteristic.
Dependency:
Refer to: p3822, p3845
p3832[0...n]
Friction characteristic, value F2 / Friction F2
SERVO (Lin)
Can be changed: T
Data type: Floating Point
P-Group: Functions
Not for motor type: REL
Min
-1000000.00 [N]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 3rd value pair of the friction characteristic.
Dependency:
Refer to: p3822, p3845
p3833[0...n]
Friction characteristic, value M3 / Friction M3
SERVO, VECTOR
Can be changed: T
(n/M)
Data type: Floating Point
P-Group: Functions
Not for motor type: REL
Min
-1000000.00 [Nm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 4th value pair of the friction characteristic.
Dependency:
Refer to: p3823, p3845
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Calculated: -
Dynamic index: DDS, p0180
Units group: 8_1
Max
1000000.00 [N]
Calculated: -
Dynamic index: DDS, p0180
Units group: 7_1
Max
1000000.00 [Nm]
Calculated: -
Dynamic index: DDS, p0180
Units group: 8_1
Max
1000000.00 [N]
Calculated: -
Dynamic index: DDS, p0180
Units group: 7_1
Max
1000000.00 [Nm]
Parameters
List of parameters
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [N]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Nm]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [N]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Nm]