Page 3
Foreword Parameters SINAMICS Function Diagrams SINAMICS S List Manual Faults and Alarms Appendix Manual List of abbreviations References Valid for Index Drive Firmware version SINAMICS 2.5 SP1 6SL3 097-2AP00-0BP6 07/2007...
Page 4
Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Page 19
1. Standard 2. Advanced 3. Expert 4. Service Please contact your local Siemens office for the password for parameters with access level 4 (Service). 5. Macro (the parameter can only be changed via macro) Note: Parameter p0003 is CU-specific (belongs to Control Unit).
Page 117
[1] = Line filter, optional Note: When a Siemens line filter is used (p0220) this parameter is automatically preset with the correct value. For a parallel circuit, the value corresponds to the capacitance of a power unit. Index 0 refers to the first line filter from p0220[0].
Page 130
If a catalog motor is selected (p0300 >= 100) and an associated motor code number (p0301), then the parameters, that are associated if this list, cannot be changed (write protection). The write protection is canceled if the motor type p0300 is set to a non-Siemens motor that matches p0301 (e.g. p0300 = 2 for p0301 = 2xxxx). Notice:...
Page 132
This also applies for parameters for a motor with DRIVE-CLiQ. In this case p0300 can only be set to p0300 = 10000 or 10001 (read motor parameters) or to the corresponding non-Siemens motor (first digit of the motor code number) in order to be able to cancel the write protection.
Page 151
= 1 contains the calculations of p0340 = 2, 3, 4, 5 without overwriting the motor parameters from the Sie- mens motor lists (p0301 > 0). p0340 = 2 calculates the motor parameters (p0350 ... p0360), but only if it does involve a Siemens catalog motor (p0301 = 0).
Page 283
Starts to download param. saved in non-volatile way w/ p0977=11 Starts to download param. saved in non-volatile way w/ p0977=12 Starts to download Siemens internal setting 20 Starts to download Siemens internal setting 21 Starts to download Siemens internal setting 22...
Page 765
When the calculations have been completed, p3900 and p0010 are automatically reset to a value of 0. When calculating motor, open-loop and closed-loop control parameters (such as for p0340 = 1) parameters associ- ated with a selected Siemens list motor are not overwritten. p3902[0...n]...