p1110[0...n]
BI: Inhibit negative direction / Inhib neg dir rot
SERVO (Extended
Can be changed: T
setp), VECTOR
Data type: Unsigned32 / Binary
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source to disable the negative direction.
Dependency:
Refer to: p1111
p1111[0...n]
BI: Inhibit positive direction / Inhib pos dir rot
SERVO (Extended
Can be changed: T
setp), VECTOR
Data type: Unsigned32 / Binary
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source to disable the positive direction.
Dependency:
Refer to: p1110
r1112
CO: Speed setpoint after minimum limiting / n_set n. min_lim
SERVO (Extended
Can be changed: -
setp), VECTOR
Data type: Floating Point
P-Group: Setpoints
Not for motor type: -
Min
- [RPM]
Description:
Displays the speed / velocity setpoint after the minimum limiting.
Dependency:
Refer to: p1091, p1092, p1093, p1094, p1101
r1112
CO: Velocity setpoint after minimum limiting / n_set n. min_lim
SERVO (Extended
Can be changed: -
setp, Lin)
Data type: Floating Point
P-Group: Setpoints
Not for motor type: -
Min
- [m/min]
Description:
Displays the speed / velocity setpoint after the minimum limiting.
Dependency:
Refer to: p1091, p1092, p1093, p1094, p1101
p1113[0...n]
BI: Direction reversal / Direction reversal
SERVO (Extended
Can be changed: T
setp), VECTOR
Data type: Unsigned32 / Binary
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for the direction reversal of the setpoint.
Dependency:
Refer to: r1198
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Max
-
Calculated: -
Dynamic index: -
Units group: 3_1
Max
- [RPM]
Calculated: -
Dynamic index: -
Units group: 4_1
Max
- [m/min]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Max
-
Parameters
List of parameters
Access level: 3
Func. diagram: 2505
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2505
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 3050
Unit selection: p0505
Expert list: 1
Factory setting
- [RPM]
Access level: 3
Func. diagram: 3050
Unit selection: p0505
Expert list: 1
Factory setting
- [m/min]
Access level: 3
Func. diagram: 2442, 2505
Unit selection: -
Expert list: 1
Factory setting
0
1-317