p1008[0...n]
CO: Fixed speed setpoint 8 / n_set_fixed 8
SERVO (Extended
Can be changed: U, T
setp), VECTOR
Data type: Floating Point
P-Group: Setpoints
Not for motor type: -
Min
-210000.000 [RPM]
Description:
Sets a value for the fixed speed / velocity setpoint 8.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
p1008[0...n]
CO: Fixed velocity setpoint 8 / n_set_fixed 8
SERVO (Extended
Can be changed: U, T
setp, Lin)
Data type: Floating Point
P-Group: Setpoints
Not for motor type: -
Min
-1000.000 [m/min]
Description:
Sets a value for the fixed speed / velocity setpoint 8.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
p1009[0...n]
CO: Fixed speed setpoint 9 / n_set_fixed 9
SERVO (Extended
Can be changed: U, T
setp), VECTOR
Data type: Floating Point
P-Group: Setpoints
Not for motor type: -
Min
-210000.000 [RPM]
Description:
Sets a value for the fixed speed / velocity setpoint 9.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
p1009[0...n]
CO: Fixed velocity setpoint 9 / n_set_fixed 9
SERVO (Extended
Can be changed: U, T
setp, Lin)
Data type: Floating Point
P-Group: Setpoints
Not for motor type: -
Min
-1000.000 [m/min]
Description:
Sets a value for the fixed speed / velocity setpoint 9.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Max
210000.000 [RPM]
Calculated: -
Dynamic index: DDS, p0180
Units group: 4_1
Max
1000.000 [m/min]
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Max
210000.000 [RPM]
Calculated: -
Dynamic index: DDS, p0180
Units group: 4_1
Max
1000.000 [m/min]
Parameters
List of parameters
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [RPM]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [m/min]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [RPM]
Access level: 2
Func. diagram: 3010
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [m/min]
1-293