5:
6:
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0489, p0490, p0728
Notice:
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
To select the values:
For CU310, CX32, NX10 and NX15, only DI/DO 9, 10, 11 can be selected as fast inputs (refer to the Equipment
Manual).
Note:
DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
Refer to the encoder interface for PROFIdrive.
If parameterization is rejected, check whether the terminal is already being used in p0580, p0680, p2517 or p2518.
p0489[0...2]
Measuring probe 2 input terminal / Meas probe 2 inp
SERVO, VECTOR
Can be changed: U, T
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the input terminal to connect probe 2.
Values:
0:
1:
2:
3:
4:
5:
6:
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0488, p0490, p0728
Notice:
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
To select the values:
For CU310, CX32, NX10 and NX15, only DI/DO 9, 10, 11 can be selected as fast inputs (refer to the Equipment
Manual).
Note:
DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
Refer to the encoder interface for PROFIdrive.
If parameterization is rejected, check whether the terminal is already being used in p0580, p0680, p2517 or p2518.
p0490
Invert measuring probe or equivalent zero mark / Meas. probe invert
CU_S
Can be changed: U, T
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Setting to invert the digital input signals to connect a measuring probe or an equivalent zero mark.
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
DI/DO 14 (X132.10)
DI/DO 15 (X132.11)
No meas probe
DI/DO 9 (X122.8/X121.8)
DI/DO 10 (X122.10/X121.10)
DI/DO 11 (X122.11/X121.11)
DI/DO 13 (X132.8)
DI/DO 14 (X132.10)
DI/DO 15 (X132.11)
Calculated: -
Dynamic index: -
Units group: -
Max
6
Calculated: -
Dynamic index: -
Units group: -
Max
-
Parameters
List of parameters
Access level: 3
Func. diagram: 4740
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 4740
Unit selection: -
Expert list: 1
Factory setting
0000 bin
1-195