p0390[0...n]
Rated excitation current / Exc I_rated
VECTOR
Can be changed: C2(1, 3)
Data type: Floating Point
P-Group: Motor
Not for motor type: ASM, PEM, REL
Min
0.00 [A]
Description:
Sets the rated current (I_F) for the excitation.
p0391[0...n]
Current controller adaptation, starting point KP / I_adapt pt KP
SERVO
Can be changed: C2(3), U, T
Data type: Floating Point
P-Group: Motor
Not for motor type: REL
Min
0.00 [Arms]
Description:
Sets the starting point of the current-dependent current controller adaptation where the current controller gain
p1715 is effective.
Dependency:
Refer to: p0392, p0393, p1402, p1715
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note:
For p0393 = 100 % or p1402 bit 2 = 0, the current controller adaptation is disabled and p1715 is effective over the
entire range.
p0391[0...n]
Current controller adaptation, starting point KP / I_adapt pt KP
VECTOR
Can be changed: C2(3), U, T
Data type: Floating Point
P-Group: Motor
Not for motor type: REL
Min
0.00 [Arms]
Description:
Sets the starting point of the current-dependent current controller adaptation where the current controller gain
p1715 is effective.
Dependency:
Refer to: p0392, p0393, p1402, p1715
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
p0392[0...n]
Current controller adaptation, starting point KP adapted / I_adapt pt KP adap
SERVO
Can be changed: C2(3), U, T
Data type: Floating Point
P-Group: Motor
Not for motor type: REL
Min
0.00 [Arms]
Description:
Sets the starting point of the current-dependent current controller adaptation where the adapted current controller
gain p1715 * p0393 is effective.
Dependency:
Refer to: p0391, p0393, p1402, p1715
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Max
10000.00 [A]
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Max
6000.00 [Arms]
Calculated: CALC_MOD_REG
Dynamic index: MDS, p0130
Units group: -
Max
6000.00 [Arms]
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Max
6000.00 [Arms]
Parameters
List of parameters
Access level: 1
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
0.00 [A]
Access level: 3
Func. diagram: 5714
Unit selection: -
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 3
Func. diagram: 6714
Unit selection: -
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 3
Func. diagram: 5714
Unit selection: -
Expert list: 1
Factory setting
0.00 [Arms]
1-167