IBM Infoprint 1130/1140
TP=High-Capacity Stacker top position sensor
P=High-Capacity Stacker pass thru sensor
F=High-Capacity Stacker bin full sensor (lower par of dual
sensor)
NF=High-Capacity Stacker near full sensor (upper part of dual
sensor)
5. Once the screen is displayed, manually actuate each of the
sensors of the High-Capacity Stacker. When the sensor is
closed CL displays, and when the sensor is open OP displays.
6. Select Return or Stop to exit the test.
5-Bin Mailbox Option
1. Select Output Bin tests from the menu.
2. Select Output Bin tests - Sensor Tests.
3. Select Sensor Tests for Output Bin x (x=number of the output
option to be tested).
4. The following screen is displayed:
Output Bin x
P1=OP P2=OP L=NL
P1=5-Bin Mailbox first pass thru sensor
P2=5-Bin Mailbox second pass thru sensor
L=EM, 5-Bin x empty
L=NL, bin contains media, but the bin is NOT near full nor full
L=NF, the bin is near full
L=FL, the bin is full
5. Once the screen is displayed, manually actuate each of the
sensors of the High-Capacity Stacker, except for the output
level sensor. When the sensor is closed, CL displays, and when
the sensor is open OP displays.
6. Select Return or Stop to exit the test.
Diagnostic Aids