IBM Infoprint 1130/1140
Print Quality - Evenly spaced horizontal lines or marks.
FRU
1
Lines spaced 3.19 mm
(.126 inch) apart
2
Lines spaced 22.32 mm
(.882 inch) apart
Lines spaced 28.7 mm
(1.130 inch) apart
Lines spaced 47.83 mm
(1.883 inch) apart
Lines spaced 63.77 mm
(2.511 inch) apart
3
Lines spaced 38.26 mm
(1.506 inch) apart
4
Lines spaced 44.64 mm
(1.757 inch) apart
5
Lines spaced 47.19 mm
(1.858 inch) apart
6
Lines spaced 49.16 mm
(1.935 inch) apart
Action
This can be caused by the motor
pinion gear on the main drive motor.
Replace the main drive motor.
This can be caused by a defective
gear in the main drive gearbox
assembly. Replace the main drive
gearbox assembly.
This can be caused by defective
gear(s) in the main drive gearbox.
Replace the FRUs in the following
order:
main drive gearbox
reference edge
Replace the FRUs in the following
order:
developer drive assembly
main drive gearbox assembly
Replace the FRUs in the following
order:
toner cartridge
charge roll
developer drive assembly
Replace the toner cartridge.
Diagnostic Information
2-113