Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water.
v Heat to more than 100°C (212°F)
v Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
To replace the battery:
1. Read the information in "Before you begin" on page 71 and follow any special
2. Turn off the server and all attached devices, and disconnect all power cords and
3. Remove the top cover as described at "Removing the server top cover and
4. Using the illustration at "System board locations" on page 65 as a reference,
5. Remove the battery, as shown in the following illustration:
24
Hardware Maintenance Manual: xSeries 360 Type 8686
handling and installation instructions supplied with the replacement battery.
external cables (see "Safety information" on page 145).
bezel" on page 72.
locate the battery on the system board.
a. Use one finger to press down slightly on one side of the battery. The other
side of the battery will tilt up out of the socket.
b. Use your thumb and index finger to pull the battery out from under the
battery clip.
c. To ensure that the battery clip will hold the replacement battery securely,
press gently on the clip so that it touches the base of the battery socket
momentarily.