Hole Locations In The Front Of The Rack; Selecting Bracket Pins For Your Rack - IBM Storwize V7000 Gen2+ Quick Installation Manual

Table of Contents

Advertisement

Figure 9. Hole locations in the front of the rack
14
Storwize V7000 Gen2 and Gen2+: Quick Installation Guide
1
2
3
1 Upper rail-mounting bracket pin
v
2 Lower rail-mounting bracket pin
v
3 Rack mounting screw hole
v
3. Ensure that the appropriate bracket pins are installed in the front and rear
bracket of each rail. Each rail comes with four medium pins preinstalled (two
in the front bracket and two in the rear bracket). Large pins are provided
separately. Use the pins that are appropriate for the mounting holes in your
rack (see Table 6).
Table 6. Selecting bracket pins for your rack
Mounting holes Bracket pins
Round,
Use the preinstalled medium pins.
unthreaded
Square
Unscrew the medium pins and replace with the large pins that are
supplied with the rails.
4. At each end of the rail, grasp the tab 1 and pull firmly to open the hinge
bracket. (See Figure 10 on page 15.)