Figure 115. Remove the rail assembly from the rear frame bracket
4. Pull the rail forward, away from the rear bracket, as shown in Figure 115.
5. Repeat step 1 on page 121 through step 4 for the other side of the rail assembly.
Replace the support rails
6. To reinstall the support rails, or replace them with support rails from FRU

Connecting optional SAS expansion enclosures: 2076-92F

After you install 5U expansion enclosures into the rack, you must connect them to
each system that will use them. The system requires software version 7.8.0 or later.
Do not connect the expansion enclosure if software version 7.8.0 is not installed on
the system.
About this task
This task applies if you are installing a 2076-92F expansion enclosure.
Note: When you insert SAS cables, ensure that the connector is oriented correctly
to the control enclosure and expansion enclosure.
v For Storwize V7000 Gen2 systems, Storwize V7000 Gen2+ control enclosures,
Figure 116. SAS cable connector orientation
v For 2076-92F 5U expansion enclosures, the blue pull tab must be above the
v Insert the connector gently until it clicks into place. If you feel resistance, the
v When inserted correctly, the connector can be removed only by pulling the tab.
Be aware of the following guidelines when you attach the cables to the SAS ports.
122
Storwize V7000 Gen2 and Gen2+: Quick Installation Guide
3
stock, follow the procedure in "Installing or replacing the support rails:
2076-92F" on page 48.
and 2U expansion enclosures, the blue pull tab must be below the cable ( 1 in
Figure 116).
1
connector ( 2 in Figure 116).
connector is probably oriented the wrong way. Do not force it.
2