17. Remove the cable management arm assembly from its packaging ( 2 in
18. Attach the cable management arm, as described in "Installing or replacing the
19. Connect the SAS cables, as described in "Removing and installing a SAS cable:
20. Connect the power cables.

Removing the top cover: 2076-92F

To complete some service tasks, you might need to remove the top cover from a
2076-92F expansion enclosure.
Before you begin
Important: You can remove the cover without powering off the expansion
enclosure. However, to maintain operating temperature, replace the cover within 15
minutes of its removal. When the cover is removed, the reduction in airflow
through the enclosure might cause the enclosure or its components to shut down
to protect from overheating.
Procedure
1. Use the slide rails to pull the enclosure out from the rack. See "Removing an
2. Slide the release latch ( 1 ) in the direction that is shown in Figure 34.
1
Figure 34. Releasing the 2076-92F cover
3. Slide the cover toward the front of the expansion enclosure ( 2 ), as shown in
4. Carefully lift the cover up, as shown in Figure 35 on page 48.
Figure 31 on page 44).
cable-management arm: 2076-92F" on page 60.
2076-92F" on page 82.
expansion enclosure from a rack: 2076-92F" on page 89 for details.
2
Figure 34.
Chapter 2. Installing the system hardware