Important: You can remove a drive assembly without powering off the expansion
enclosure. However, to maintain operating temperature, complete the following
tasks.
v Do not remove a faulty drive assembly until its replacement is ready to be
v Do not keep the cover off an operational enclosure for more than 15 minutes.
About this task
The 2076-92F expansion enclosure supports 92 drives. Figure 92 shows an example
of a drive assembly.
2
3
4
Figure 92. Drive assembly
Procedure
1. Read all available safety information.
2. Use the slide rails to pull the enclosure out from the rack, as described in
3. Remove the top cover, as described in "Removing the top cover: 2076-92F" on
4. Locate the slot that contains the drive assembly that you want to remove.
100
Storwize V7000 Gen2 and Gen2+: Quick Installation Guide
installed.
The reduction in airflow through the enclosure might cause the enclosure or its
components to shut down to protect from overheating.
1
1 Disk drive
2 Online indicator
3 Fault indicator
4 Release latch
5 Drive latch toes
6 Drive carrier
"Removing an expansion enclosure from a rack: 2076-92F" on page 89.
page 47.
Note: When a drive is faulty, the amber fault indicator is lit ( 3 in Figure 92).
Do not replace a drive unless the drive fault indicator is on or you are
instructed to do so by a fix procedure. When lit, the green indicator shows that
activity is occurring on the drive.
A label on the enclosure cover (Figure 93 on page 101) shows the location of the
drive slots. The drive slots are numbered 1-14 from left to right and A-G from
the back to the front of the enclosure.