10.3 Technical data
10.3

Technical data

General information
Brand name of the product
Product category
Product description
Monitoring application
Measured motor parameters
Calculated motor parameters
Other motor parameters
Supported motors
Type of installation / mounting
Type of mounting and position
Qualified adhesives
Power supply
Type of power supply
 
Life of the battery
Memory
Internal flash memory
Communication
Bluetooth ®
206
SIMOTICS CONNECT 400
Sensor and communication device
SIMOTICS CONNECT 400 with integrated sensors monitors the condition of the
motor to provide information about motor operation and to enable optimization of
the application and process.
SIMOTICS CONNECT 400 can only be used in combination with the "SIDRIVE IQ Fleet"
MindSphere application.
Data analyses, based on the digital twin of the motor, and the visualization of the
motor condition are offered comprehensively in the SIDRIVE IQ Fleet MindSphere
application.
Temperature, radial/tangential/axial vibration, electrical stator frequency, slip fre‐
quency
Motor status (on/off), speed, torque*, electrical energy*, energy consumption*,
number of motor starts, operating hours
* currently not available in converter operation (VSD)
Maintenance demanded, e.g. regreasing interval
Three-phase, rib-cooled low-voltage asynchronous motors in line operation (DOL)
and in converter operation (VSD),
IEC shaft heights 80 to 450 and NEMA shaft heights 48 to 680
Mounted outside using a (glued) mounting bracket* on the cooling ribs of the
motor.
* As described in the installation instructions.
Henkel LOCTITE® HY 4090™, Weicon Fast Metal Minute Adhesive, 3M Scotch-
Weld DP 8407 NS
Battery pack included
Li/SOCl
3.6 V, 4 cells, size AA, non-rechargeable
2,
Operating time up to 2 years*, replaceable to prolong the life
* At an ambient temperature of 0° C to 40° C and with a measurement interval of 5 minutes and transmission of the stored data once every
24 hours
Data storage for at least 48 hours* if the MindSphere connection is interrupted
* At a measuring interval of 1 minute
SPBTLE-RF Bluetooth module for communication with a mobile device for commis‐
sioning and configuring the connectivity module
Compliant with Bluetooth ® V4.1
Frequency: 2402 GHz – 2480 GHz
RF output power: 2402 – 2480 MHz: 4.20 dBm (Max. e.i.r.p.)
Range: up to 10 m
* Commissioning comprises the integration into the local Wi-Fi network and onboarding to MindSphere.