hit counter script

IBM ThinkPad 340 Series Hardware Maintenance Manual page 94

Table of Contents

Advertisement

Symptom/Error
000187XX
000188XX
000189XX
00019000
00019102
000191XX
(Not listed above)
00019200
00019201
00019202
00019300, 00019301
00019305
00019302
00019303
00019304
00019306
00019400
000199XX
0001XXXX
(not listed above)
000215XX
(720, 720C only)
84
IBM Mobile Systems HMM
FRU/Action
1. Set Configuration
2. System Board
1. System Board
1. Select More utilities
to clear the system
error log.
1. Reseat System Board
2. Reseat CPU chip /
Processor Card
3. System Board
1. Rerun diagnostics
tests.
2. If error remains, see
000191XX.
1. Reseat System Board
2. Reseat CPU chip /
Processor Card
3. System Board
1. Voltage Converter
2. Keyboard Control Card
3. System Board
1. Voltage Converter
1. Run System Unit
Diagnostic.
If this error message
appears frequently,
replace the Processor
Card.
1. System Board
1. Hard Disk Drive
2. System Board
1. System Board
2. Diskette Drive
1. PC Card
2. System Board
1. Keyboard Control
Card
2. Keyboard
3. Pointing Device
1. Processor Card
1. System Board
1. System Board
2. Processor Card
1. Reseat Base Memory
Card (interface
connector on system
board).

Advertisement

Table of Contents
loading

Table of Contents