IBM ThinkPad 340 Series Hardware Maintenance Manual page 227

Table of Contents

Advertisement

Numeric Error Codes
Symptom/Error
10X
110
111
118
(Memory parity error was
logged in CMOS.)
(Go to "Memory Checkout"
on page 201.)
158
(HDP was not set even
though the supervisor
password is set.)
159
(HDP is not set the same as
the supervisor password.)
161
163
(Time and Date was not
set.)
173
(Configuration data were
lost.)
174
(Perform "Checking the
Installed Devices List" on
page 230 before changing
any FRUs.)
175, 177, 178
183
(Incorrect password entered
at the supervisor password
prompt.)
184
(POP check sum error.)
ThinkPad 355x, 360x, 370C, 750x, 755C, 755Cs
FRU/Action
1. System Board
1. Go to "Memory
Checkout" on
page 201.
2. IC DRAM Card or
DIMM Card
3. System Board
1. Go to "Memory
Checkout" on
page 201.
2. Expansion Unit/Port
Replicator
3. System Board
1. Run memory
diagnostics to clear
the error log.
1. Set a HDP.
1. Set a correct HDP.
1. Go to "Checking the
Backup Battery" on
page 211.
2. Backup Battery
3. System Board
1. Set Time and Date.
2. System Board
1. Select OK in the error
screen; then set time
and date
2. Backup Battery
3. System Board
1. Check Device
Configuration.
2. System Board
3. Diskette Drive
Assembly
4. Hard Disk Drive
Assembly
1. System Board
1. Have the user
examine the
password.
1. Reset the POP in
Easy-Setup.
217