Symptom/Error
173
(Configuration data were
lost.)
174
(Perform "Checking the
Installed Devices List" on
page 422 before changing
any FRUs.)
175, 177, 178
183
(Incorrect password entered
at the supervisor password
prompt.)
184
(POP check sum error.)
185
(The startup sequence is
not valid. Suspect that
power was off when the
startup sequence was being
updated.)
186
188
190
(Depleted battery pack was
installed when the power
was on.)
191XX
196
(Read error occurred in the
hibernation area of the
HDD.)
199XX
1XX
2XX
ThinkPad 755CE, 755CSE, 755CV, 755CX (9545)
FRU/Action
1. Select OK in the error
screen; then set time
and date.
2. Backup Battery
3. System Board
1. Check Device
Configuration.
2. System Board
3. Diskette Drive
Assembly
4. Hard Disk Drive
Assembly
1. System Board
1. Have the user
examine the
password.
1. Reset the POP in the
Easy-Setup.
1. Reset the startup
sequence in the
Easy-Setup.
1. System Board
1. Set the system
identification using
the ThinkPad 750Ce
hardware
maintenance diskette.
1. Go to "Checking the
Battery Pack" on
page 399.
1. System Board
2. Processor card
1. Run the hard disk
drive test.
2. Hard Disk Drive
1. System Board
1. System Board
1. Go to "Memory
Checkout" on
page 393.
2. IC DRAM Card, DIMM,
or DIMM Adapter
3. System Board
409