Nways Switch Administration Station FRU Exchange
Before any FRU exchange from the Nways Switch administration station you must
remove the Nways Switch administration station from the rack following the above
procedure.
Nways Switch Administration Station Removal from the Rack
1. Power off the display and the Nways Switch administration station using their
2. At the rear of the Nways Switch administration station disconnect all the cables.
Figure 5-1. NAS Cables Connection
3. If the Nways Switch administration station is installed:
5-2
2220 Setup and Service Guide
respective power ON/OFF switches located on the front panels.
CAUTION
Be careful, the weight of the Nways Switch administration station is about
16 kg (35.3 lb).
v On a table go to "FRU Exchange" on page 5-8.
v In a 29U rack:
– If you have the earthquake feature installed, go to "NAS Removal From
the 29U Rack (Earthquake Feature)" on page 5-6.
– If you do not have the earthquake feature, go to "NAS Removal From the
29U Rack (Standard)" on page 5-6.
v In a 37U rack:
– If you have the earthquake feature installed, go to "NAS Removal From
the 37U Rack (Earthquake Feature)" on page 5-3.
– If you do not have the earthquake feature, go to "NAS Removal from the
37U Rack (Standard)" on page 5-3.