Table 1. DS300 and DS400 storage subsystems operating specifications
Size (measured from front of hard disk
drive to rear of unit)
v Depth: 584 mm (23.0 in.)
v Height: 128 mm (5.0 in)
v Width: 442 mm (17.4 in)
Heat output
v 558 watts (1903.96 Btu/hr)
Weight
v Standard storage server as shipped
(without hard disk drives): 48.2 kg
(106 lb)
v Standard storage server as shipped
(with 14 hard disk drives): 62.2 kg
(137 lb)
v Unit weight (without hard disk drives):
25.9 kg (57 lb)
v Unit weight (with hard disk drives):
39 kg (86 lb)
Inventory checklist
After you unpack the storage subsystem, make sure that you have the items that
are described in this section.
Hardware
The IBM TotalStorage DS300 storage subsystem (1701-1RL) comes with the
following components:
v One iSCSI RAID controller
v One power-supply-with-fan unit
v Seven hard disk drive filler panels
The IBM TotalStorage DS300 storage subsystem (1701-1RS) comes with the
following components:
v One iSCSI RAID controller
v 14 hard disk drive filler panels
v Two power-supply-with-fan units
IBM TotalStorage DS400 storage subsystem (1700-1RS) comes with the following
components:
v One Fibre Channel RAID controller
v 14 hard disk drive filler panels
v Two power-supply-with-fan units
The following hardware comes with all storage subsystem models:
v Rack-mounting hardware kit (1)
v Ethernet wrap plug (for diagnostic purposes only)
4
IBM TotalStorage DS300 and DS400: Hardware Installation and User's Guide
Electrical input
v Sine-wave input (50 to 60 Hz) is
required
v Input voltage:
– Low range:
- Minimum: 90 V ac
- Maximum: 136 V ac
– High range:
- Minimum: 198 V ac
- Maximum: 264 V ac
– Input kilovolt-amperes (kVA)
approximately:
- Minimum configuration: 0.06 kVA
- Maximum configuration: 0.56 kVA
– Two rack support rails (right and left assembly)
– Ten M6 hex screws
– Ten M6 cage nuts
– Ten M6 clip nuts
Environment
v Air temperature:
– Storage server on:
10° to 35°C
(50° to 95°F)
Altitude: 0 to 914 m (3000 ft)
– Storage server on:
10° to 32°C
(50° to 90°F)
Altitude: 914 m (3000 ft) to 2133 m
(7000 ft)
v Humidity:
– 8% to 80%