Page 1
Hardware Maintenance Manual xSeries 330 Type 8675...
Page 2
This publication was developed for products and services offered in the United States of America. IBM may not offer the products, services, or features discussed in this document in other countries, and the information is subject to change without notice.
What the xSeries 330 offers Reliability, availability, and serviceability features . Installing options ..45 Server controls and indicators Major components of the xSeries 330 server . 46 Front view . System board .
Page 4
. 168 No Beep symptoms . . 115 Problem determination tips. . 169 Information panel system error LED. . 115 Notices . 169 Diagnostic error codes . . 117 Trademarks . . 170 Hardware Maintenance Manual: xSeries 330 Type 8675...
« xSeries 330 Type 8675. Important: This manual is intended for trained servicers who are familiar with IBM PC Server products. Before servicing an IBM product, be sure to review “Safety information” on page 135. Important safety information Be sure to read all caution and danger statements in this book before performing any of the instructions.
Lea atentamente todas las declaraciones de precaución y peligro ante de llevar a cabo cualquier operación. Online support Use the World Wide Web (WWW) to download Diagnostic, BIOS Flash, Device Driver files and documents. The Web address is: http://www.ibm.com/pc/support Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 8
20. If you receive an error, go to “Symptom-to-FRU index” on page 113. If the diagnostics completed successfully and you still suspect a problem, see “Undetermined problems” on page 128. Hardware Maintenance Manual: xSeries 330 Type 8675...
IBM Memory eXpansion Technology (MXT) on the xSeries 330 Type 8675 effectively expands the memory capacity of the server when an MXT-aware operating system is running on the server.
– Maximum: 0.22 kVA What the xSeries 330 offers The unique design of this server takes advantage of advancements in symmetric multiprocessing (SMP), data storage, and memory management. The server combines: v IBM X-Architecture ™ Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 11
DIMM. The IBM Memory eXpansion Technology (MXT) chip on your server enables you to store up to nearly twice the amount of data in system memory as was previously possible.
SCSI backplane v Vital Product Data (VPD) on system board, and SCSI backplane Server controls and indicators This section identifies the controls and indicators on the front and the back of your server. Hardware Maintenance Manual: xSeries 330 Type 8675...
Front view Select button/indicator Power control (green) button Diskette drive Power-on System error activity light light (green) light (amber) (green) Reset button Diskette eject button CD activity CD eject button light (green) Power-control button: Press this button to manually turn the server on or off. Power-on light: This green LED lights and stays on when you turn on your server and blinks when the server is in Standby mode.
Power-on light: This green LED lights and stays on when you turn on your server and will blink when the server is in standby mode. This light duplicates the power on light on the front of the server. Hardware Maintenance Manual: xSeries 330 Type 8675...
Ethernet 2 link indicator: This green LED lights when there is an active link connection on the 10BASE-T or 100BASE-TX interface for Ethernet port 2. Ethernet 2 speed indicator: This green LED lights when the speed of the Ethernet LAN connected to Ethernet port 2 is 100 Mbps. Turning on the server Turning on the server refers to the act of plugging the power cord of your server into the power source and starting the operating system.
View the temperature, voltages, fans, or service processor status monitors 3 - Error Logs View the system error log or the service processor error 4 - SP configuration View the service processor configuration Hardware Maintenance Manual: xSeries 330 Type 8675...
Selection Meaning 5 - System Services View information about the settings for system services 6 - System Power View settings or turn server power on or off 7 - Boot Restart the server (server power must be on) or the service processor.
Page Up Prefix followed by Ctrl-u Page Down Prefix followed by Ctrl-d Alt-F1 Prefix followed by F1 Ctrl-Alt-Del Prefix followed by Ctrl-r Note: If one prefix does not work, use the other instead. Hardware Maintenance Manual: xSeries 330 Type 8675...
Note: If the server does not have a hard disk drive, ignore any message that indicates that the drive is not installed. You will get these messages only when running the SCSISelect Utility. See “SCSI error codes” on page 125. Hardware Maintenance Manual: xSeries 330 Type 8675...
Table 2. SCSI messages SCSI Messages Description One or more of the following might be causing the problem. v A failing SCSI device (adapter, drive, controller) v An improper SCSI configuration v Duplicate SCSI IDs in the same SCSI chain v An improperly installed SCSI terminator v A defective SCSI terminator v An improperly installed cable...
Diagnostic programs and error messages The server diagnostic programs are stored in upgradable read-only memory (ROM) on the system board. These programs are the primary method of testing the major components of the server. Hardware Maintenance Manual: xSeries 330 Type 8675...
Sometimes the first error to occur causes additional errors. In this case, the server displays more than one error message. Always follow the suggested action instructions for the first error message that appears. The following sections contain the error codes that might appear in the detailed test log and summary log when running the diagnostic programs.
To save the test log so that you can view it later, click Save Log on the diagnostic programs screen and specify a location and name for the saved log file. Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 25
2. To save the test log to a diskette, you must use a diskette that you have formatted yourself; this function does not work with preformatted diskettes. If the diskette has sufficient space for the test log, the diskette may contain other data.
Use the ServerGuide program to make a BIOS flash diskette. v Download a BIOS flash diskette from the World Wide Web. Go to http: //www.pc.ibm.com/support/, select IBM Server Support, and make the selections for your server. To recover the BIOS: 1.
8. When prompted as to whether you want to save the current code to a diskette, select N. 9. When prompted to choose a language, select a language (from 0 to 7) and press Enter to accept your choice. 10. Do not restart your system at this time. 11.
Notes: 1. Listing these device drivers does not imply that these operating systems are supported on this server. Refer to http://www.ibm.com/ on the World Wide Web for the supported operating systems for the server. 2. Although the term ″adapter″ is used in these messages, the messages might also apply to the integrated Ethernet controller on the system board.
Page 29
1. From the Windows 2000 desktop, click Start Settings Control Panel Network and Dial-up connections. 2. Right-click the connection that uses your IBM Ethernet adapter, and click Properties. 3. Click Configure Advanced. 4. Lower the resource values that apply to the transmit queue.
Page 30
Explanation: Single adapter found but multiple instances tried to load. Action: Using the Configuration/Setup utility, make sure that Ethernet is enabled, and that the slot containing the IBM Netfinity 10/100 Ethernet Adapter or the IBM 10/100 Etherjet PCI adapter is enabled. 0x17 Explanation: Slot parameter not specified in the registry.
Table 6. NDIS (Windows NT or Windows 2000) driver teaming messages for the Ethernet controller (continued) Event ID Type Description Warning Explanation: Team nn. Adapter link down. Action: Make sure the adapter is functioning properly. Informational Explanation: Team nn. Secondary adapter took over. Action: None. Warning Explanation: Team nn.
CAUTION: When replacing the battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
b. Use one finger to slightly slide the battery out from its socket. The spring mechanism will push the battery out toward you as you slide it from the socket. c. Use your thumb and index finger to pull the battery from under the battery clip.
Page 34
See “Features and specifications” on page 6. Note: The server is not designed to operate in an enclosed environment. The xSeries 330 should not reside behind a glass door in its rack enclosure. For more information on specific temperature error messages, see “Temperature error messages”...
ServerGuide CDs The ServerGuide CDs include software setup and installation tools specifically designed for IBM servers. You can use these CDs during the initial installation of your server to configure the server hardware and simplify your network operating system installation. The ServerGuide CDs also contain a collection of application programs, which you can install after your server is up and running.
Select this choice to display information about the server. Changes that you make on other menus might appear on this summary screen. You cannot edit any fields. The System Information choice appears only on the full Configuration/Setup Utility main menu. – Product Data Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 37
Select this choice to view system information, such as the machine type and model, the server serial number, and the revision level or issue date of the code, such as BIOS, stored in the flash electronically erasable programmable ROMs (EEPROMs). –...
Page 38
Select this choice to identify if the microprocessor serial number in the microprocessor is readable, or to set the microprocessor cache mode to disabled, write-back (WB), or write-through (WT). Selecting write-back mode will provide better system performance. Hardware Maintenance Manual: xSeries 330 Type 8675...
– Core Chipset Control Select this choice to modify settings that control features of the core chip set on the system board. v Error Logs Select this choice to view or clear error logs. – Select POST Error Log to view the three most recent error codes and messages that the system generated during POST.
Configuration/Setup Utility main menu. You can set, change, or delete both the administrator and power-on passwords, and allow a power-on password to be changed by the user. Hardware Maintenance Manual: xSeries 330 Type 8675...
The server must be running an MXT-aware operating system, such as Microsoft Windows 2000 after the IBM MXT device driver has been installed or Red Hat Linux 7.2. v Any required MXT device driver for that operating system must be installed and loaded.
SCSI controller to its default values, press F6; then, follow the instructions that appear on the screen. You can view or change the following controller settings: – SCSI Controller ID Select this choice to view the SCSI controller ID, normally 7. Hardware Maintenance Manual: xSeries 330 Type 8675...
– SCSI Controller Parity Select this choice to view the assigned value. The assigned value is Enabled, and it cannot be changed. – SCSI Controller Termination Select this choice to view the assigned value. The assigned value is Enabled, and it cannot be changed. –...
Page 44
Select this choice to enable or disable the legacy operating system wake-up support. – Disabled (default) – Enabled Notes: 1. Use the default setting for Advanced Configuration and Power Interface ® (ACPI) aware operating systems, such as Windows 2000 and Windows NT Hardware Maintenance Manual: xSeries 330 Type 8675...
To update the Advanced System Management (ASM) firmware or configure the ASM processor, you must download the image of the Advanced System Management Firmware Update Utility program from the IBM Support page at http://www.ibm.com/pc/support on the World Wide Web. Use the Advanced System Management Firmware Update Utility program to create an Advanced System Management Firmware Update Utility diskette which you can then use to update the ASM firmware or configure ASM processor settings.
Profile. When you have selected a User Profile, you can set the following values: v Login ID v Password v Enable or disable the currently selected entry v Number v PIN v Connection Type (numeric, alphanumeric, serial) Hardware Maintenance Manual: xSeries 330 Type 8675...
Select this choice to update configuration settings for the ASM processor. For more information, see “Updating the ASM firmware” on page 41. Exit Select this choice to exit from the xSeries 330 Type 8675 Advanced System Management Firmware Update Utility program. Configuring the ASM processor To configure the ASM processor, do the following: 1.
“Choices available from the Configuration/Setup main menu” on page 32 for more information. 2. Go to http://www.ibm.com/pc/support on the World Wide Web and locate the section for the server. If a system BIOS or diagnostics downloadable file has a version level that is later than the version level on your server, download that file and the associated README file.
Major components of the xSeries 330 server The following illustration shows the locations of major components in the server. Air baffle Clip Terminator card Heat sink Memory module Microprocessor Fans Light Path Diagnostics panel Hard disk drive filler panel Hard disk drive...
System board options connectors The following illustration identifies the connectors on the system board. C2T (in) USB 1 Management connector connector connector (U38) (J13) (J65) Serial C2T (out) USB 2 RS-485 Advanced System connector B connector connector Management processor (J39) Serial (U61) (J15)
Make sure that you have an adequate number of properly grounded electrical outlets for the server, monitor, and any other options that you intend to install. Hardware Maintenance Manual: xSeries 330 Type 8675...
Have a small, flat-blade screwdriver available. v For a list of supported options for the server, refer to http://www.ibm.com/pc/us/compat/ on the World Wide Web. v For your convenience during setup and service you might want to have a separate location where you can temporarily connect the server to a power source (using a separate power cord), keyboard, monitor, and mouse (using a separate C2T device breakout cable).
Page 54
3. Using the thumb screws on the front of the server; secure the server to the brackets. Thumb screw (server) 4. If you have additional servers to install, repeat steps 1 through 3 for each server. 5. Install all external cables and power cords to the server. Hardware Maintenance Manual: xSeries 330 Type 8675...
Removing the cover The following information describes how to remove the cover. Cover release Screws lever Complete the following steps to remove the cover from the server: 1. Review the information in “Before you begin” on page 48. 2. Turn off the server and all attached devices and disconnect all external cables and power cords.
Page 56
Hardware Maintenance Manual: xSeries 330 Type 8675...
Working with adapters The server comes with two peripheral component interconnect (PCI) adapter slots on the system board with riser cards installed in them. Note: Your server also comes with an integrated video controller on the system board. When you install a video adapter in a PCI slot, the server BIOS automatically disables the integrated video controller.
“Removing the cover” on page 51. Cover release Screws lever 4. Remove the expansion slot clip that holds the expansion slot cover in place by sliding it upward and off the frame of the server. Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 59
Note: The illustrations in this document might differ slightly from your hardware. Expansion slot clip Expansion slot cover Expansion slot 5. Remove the expansion-slot cover. 6. Refer to the documentation that comes with your adapter for any cabling instructions. Notes: a.
Page 60
Attention: Route cables so that they do not block the flow of air from the fans. Note: When installing a ServeRAID to control the internal hard disk drives, remove the cable from the SCSI connector (J4) on the system board and Hardware Maintenance Manual: xSeries 330 Type 8675...
11. Turn on the server. The IBM Remote Supervisor Adapter The IBM Remote Supervisor Adapter can be installed in the xSeries 330. To update the Advanced System Management (ASM) firmware or configure the ASM processor, you must download the image of the xSeries 330 Advanced System Management Firmware Update Utility program from the IBM Support page at http://www.ibm.com/pc/support on the World Wide Web.
(MIB) on your SNMP manager. If you do not want to install the most recent device drivers, the MIB is provided in the \MIB directory on the IBM Remote Supervisor Adapter Support CD that comes with the Remote Supervisor Adapter.
Page 63
v Remote graphics console redirection v LAN, serial, and Advanced System Management (ASM) interconnect remote access v Point-to-point protocol (PPP) support v Simple Network Management Protocol (SNMP) and e-mail alerts v Domain Name System (DNS) and Dynamic Host Configuration Protocol (DHCP) support v Remote power control v Microsoft Windows NT and Windows 2000 blue-screen capture...
The Remote Supervisor Adapter option contains the following items: v Remote Supervisor Adapter v Power-supply adapter v Power cord v 20-pin ribbon cable v Advanced System Management link cable (CAT 5 Ethernet cable) Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 65
Attention: To avoid damage to the Ethernet connector on the Remote Supervisor Adapter, do not plug the ASM Interconnect module into the Ethernet (RJ-45) port. v IBM Remote Supervisor Adapter Support CD This CD helps you configure hardware and install device drivers. v IBM Documentation CD...
Installing the Remote Supervisor Adapter Attention: When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling static-sensitive devices, see “Handling static-sensitive devices” on page 138. Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 67
Your server comes with riser cards installed in the two peripheral component interconnect (PCI) adapter slots on the system board. The following illustration shows the location of the 33 MHz PCI expansion slots on the system board. PCI slot 2 64 bit 33 MHz (J23) PCI slot 1...
Page 68
(see “Inventory checklist” on page 60), which connects the system management connector on the Remote Supervisor Adapter to the system board at J57 (see “System board options connectors” on page 47), also supplies power to the adapter. Hardware Maintenance Manual: xSeries 330 Type 8675...
Attention: Route cables so that they do not block the flow of air from the fans. 8. Replace the cover on the server; then, reinstall the server in the rack (if applicable) and connect all external cables. 9. Connect the ASM Interconnect module to the Remote Supervisor Adapter using the ASM Interconnect port (P-P port) that is located on the adapter.
For the cabling procedure, see: Supervisor Adapter Supervisor Adapter ASM Web interface using LAN using the Ethernet port “Cabling the Ethernet LAN the HTTP protocol port” on page 67 Text-based user interface using the TELNET protocol Hardware Maintenance Manual: xSeries 330 Type 8675...
Table 9. Cabling tasks to enable remote access to the Remote Supervisor Adapter (continued) User interface to Remote Connection to Remote For the cabling procedure, see: Supervisor Adapter Supervisor Adapter Text-based user interface Serial (COM) port “Cabling the serial (COM) using a modem or a null port”...
You can use the IBM Remote Supervisor Utility program to check the firmware level on the Remote Supervisor Adapter and to update the firmware. This Utility program is a DOS utility on the IBM Remote Supervisor Adapter Support CD that comes with the Remote Supervisor Adapter. You can obtain the latest firmware code from the IBM Support Web site, http://www.ibm.com/pc/support.
Page 73
For information about using the ASM Web interface to monitor your server, see the IBM Remote Supervisor Adapter User’s Guide for the xSeries 330, which is available in Adobe Acrobat Portable Document Format (PDF) on the IBM Documentation CD. To update the Remote Supervisor Adapter firmware, complete the following steps: 1.
Page 74
8. When the Remote Supervisor Adapter firmware update process is complete, press Enter to return to the Utility program main window. Continue with “Configuring your system to enable remote access to the Remote Supervisor Adapter” on page 71. Hardware Maintenance Manual: xSeries 330 Type 8675...
PPP For detailed information about using the ASM Web interface and the text-based user interface, see the IBM Remote Supervisor Adapter User’s Guide for the xSeries 330. Configuring the Ethernet settings If you have an accessible, active, and configured dynamic host configuration protocol (DHCP) server on your network, the hostname, IP address, gateway address, subnet mask, and DNS server IP address are set automatically.
Page 76
IP Address Type the IP address of the Remote Supervisor Adapter. Subnet Mask Type the subnet mask used by the Remote Supervisor Adapter. The default value is 255.255.255.0. Gateway Type your network gateway router. Hardware Maintenance Manual: xSeries 330 Type 8675...
2. 2. Turn on the server. 3. Insert the IBM Remote Supervisor Adapter Support CD into the CD-ROM drive and close the CD-ROM drive before the server completes POST. The CD starts automatically and the IBM Remote Supervisor Utility window opens.
Note: The data bits value is preset to 8 and cannot be changed. For detailed information about the serial port and modem settings, see the IBM Remote Supervisor Adapter User’s Guide for the xSeries 330. 7. If you make changes to the serial port settings, press F6 to apply the changes.
Page 79
2. 2. Turn on the server. 3. Insert the IBM Remote Supervisor Adapter Support CD into the CD-ROM drive and close the CD-ROM drive before the server completes POST. Note: If you do not insert the CD and close the CD-ROM drive before POST completes, you must restart the server with the CD in the CD-ROM drive.
Note: You do not need to restart the server if you are running the Windows NT operating system. 2. See the IBM Remote Supervisor Adapter User’s Guide for the xSeries 330 for detailed instructions about completing the configuration of the Remote Supervisor Adapter features.
ASM interconnect network bus. If your server has an integrated RS-485 ASM interconnect port (the xSeries 330 server has an integrated ASM interconnect port) you do not need to install an ASM Interconnect module between servers. However, you still need to install an ASM Interconnect module to connect the Remote Supervisor Adapter to the ASM processor.
ASM Interconnect modules or CAT 5 or CAT 3 Ethernet cables. This table lists some of the IBM Netfinity and IBM xSeries products and indicates if they have an integrated RS-485 ASM interconnect connection, or if you need to use an ASM Interconnect module to set up the ASM interconnect network.
Netfinity 6000R or xSeries 350 Netfinity 7600 Netfinity 7100 Installing the ASM Interconnect module on the xSeries 330 The ASM Interconnect module connects the Remote Supervisor Adapter to the ASM interconnect network. This module comes with the Remote Supervisor Adapter option. For detailed instructions about installing the ASM Interconnect module on servers with ASM processors and ASM PCI adapters, see the documentation that comes with those devices.
In the following example, a Remote Supervisor Adapter is installed in an xSeries 330 server. The xSeries 330 server with the Remote Supervisor Adapter will act as the gateway interconnect network, forwarding system-management data generated by the other systems in the ASM interconnect network bus to the system-management administration system that is connected to the network.
Page 85
In the following example, a Remote Supervisor Adapter is installed in an xSeries 330 server. This view shows the top server in a rack of xSeries servers with a Remote Supervisor Adapter installed. The xSeries 330 with the Remote Supervisor Adapter will act as the network interconnect, forwarding system-management data generated by the other systems in the ASM interconnect network bus to the system management administration system that is connected to the network.
The drive is a hot-swappable, SCSI, low voltage differential (LVD) drive with a single connector attached (SCA) connector v A SCSI backplane is installed in your system v A ServeRAID adapter that is configured as RAID 1 is installed in your system Hardware Maintenance Manual: xSeries 330 Type 8675...
If you use any other ServeRAID or SCSI configuration, you cannot hot-swap a hard disk drive; you must turn the server off and unplug the power cord before installing or replacing the drive. Each hot-swap hard disk drive tray has a status and an activity light located on the upper-right corner of tray.
If the amber light flashes rapidly (three flashes per second), the controller is identifying the drive. Working with memory The xSeries 330 supports 256 MB, 512 MB, and 1 GB 133 MHz, ECC, SDRAM, registered x4 (Chipkill) DIMMs. Note: Chipkill Memory protection is disabled if any DIMM in your server is not an x4 DIMM.
About MXT memory The IBM MXT technology on the server expands the capacity of the DIMMs installed on the server. Depending on the applications running and the load on the system, MXT can expand your server usable memory to nearly twice the amount of physical memory.
Page 90
To avoid breaking the retaining clips or damaging the DIMM connectors, handle the clips gently. 6. Install the DIMM in the connector. Attention: To prevent damage to the DIMM connectors do not force the memory module into the connector. Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 91
a. Push the retaining clip at either end of the connector away from the connector to open it for the DIMM. DIMM 2 DIMM 1 DIMM 4 Connector 1 Connector 2 Connector 3 Connector 4 b. Turn the DIMM so that the index slots align correctly with the connector. Note: The DIMM has two index slots, one in the center and the other on the left half of the DIMMS connector edge.
2, the two microprocessors will share the system load after the system has started. The following illustration shows the locations of the microprocessors on the system board. Microprocessor 2 (U79) Microprocessor 1 (U47) Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 93
When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details on handling these devices, refer to the following Web site and use a search term of ESD: http://www.ibm.com/ 1. Review the safety precautions listed in “Safety information” on page 135.
Page 94
Align and place the clip over the heat sink; then, snap the clip into place over the heat sink with the heat sink release lever in the up position. Note: If you remove the microprocessor later, remember to install the terminator card in the appropriate microprocessor connector. Hardware Maintenance Manual: xSeries 330 Type 8675...
d. When the clip is in place, press the heat sink release lever down into the locked position. Slot Heat sink release lever Clip Heat sink Top view of Microprocessor heatsink Terminator card 8. Replace the cover on the server; then, reinstall the server in the rack and connect all external cables and power cords.
Page 96
10. Start up the system. The system-error light will either remain on or turn off. If the system-error light remains on you will have to turn off the server to perform further troubleshooting. Hardware Maintenance Manual: xSeries 330 Type 8675...
Installing the cover To install the server cover: 1. Clear any cables that might impede the replacement of the cover. Important: Before sliding the cover forward, make sure that all of the tabs on the cover will engage the ledge at the front of the server properly. If all the tabs do not engage teh ledge properly, it will be extremely difficult to remove the cover later.
Configuration/Setup Utility main menu. Serial-port connector The following table shows the pin-number assignments for the 9-pin, male D-shell serial-port connector on the rear of the server. These pin-number assignments conform to the industry standard. Hardware Maintenance Manual: xSeries 330 Type 8675...
Table 12. Serial-port connectors pin-number assignments Signal Signal Data carrier detect Data set ready Receive data Request to send Transmit data Clear to send Data terminal ready Ring indicator Signal ground Universal Serial Bus ports The server has two Universal Serial Bus (USB) connectors. USB is a serial interface standard for telephony and multimedia devices.
Page 100
330 server. Connect a C2T breakout cable to the C2T (Out) connector of the last server in the chain; then, connect your monitor, keyboard, and pointing device to the device breakout cable. Hardware Maintenance Manual: xSeries 330 Type 8675...
Note: The C2T breakout cable is available in the C2T cable option kit. Video Mouse Keyboard C2T breakout cable A keyboard, monitor, and mouse or pointing device, are connected to the server through the C2T breakout cable. The keyboard and mouse cables have icons of a keyboard and a mouse on their respective cable connectors for easy identification.
Page 102
Auxilliary-device (pointing device) connector There is one auxilliary-device connector that supports a mouse or other pointing device on the end of the C2T breakout cable. This connector is identified by the mouse icon. Hardware Maintenance Manual: xSeries 330 Type 8675...
The following table shows the pin-number assignments for the auxilliary -device connector on the end of the cable. Table 16. Auxilliary or pointing-device-connector (6-pin female) pin-number assignments Signal Data Not connected Ground +5 V dc Clock Not connected Ethernet ports The server comes with two integrated Ethernet controllers.
Page 104
Because you set this priority at the host or entry point of the network, the network devices can base forwarding decisions on priority information defined in the packet. Priority Packet information is available at: http://www.ibm.com/ (search for″packet priority″) and from the Intel support Web site (http://support.intel.com/).
Page 105
The other devices receiving and routing 802.1p tagged packets must support 802.1p. v The adapters on these devices must support 802.1p. The Ethernet controller in all IBM 10/100 Ethernet Security Adapters and IBM 10/100 Ethernet Server Adapters support 802.1p. v The adapter cannot be assigned to an adapter team.
This port uses a standard D-shell serial-port connector, labeled ″A″ on the rear of the server. When this serial port connector is attached to connector J65 on the system boar, it functions as a dedicated Management port. In this mode, you can Hardware Maintenance Manual: xSeries 330 Type 8675...
Rack installation considerations For air flow reasons, observe the following practices in the rack cabinet in which the xSeries 330 server is installed: v Do not install any equipment that cools from back to front in the same rack as the xSeries 330 server.
Before you begin, review the following: v The ASM bus is designed to connect up to 12 units or servers. When using the IBM Remote Supervisor Adapter, you can connect a maximum of 11 units or servers together. v You can hot-swap the cables in the ASM bus.
5. Connect a cable from the RS-485 (B) connector of the next-to-last server to the RS-485 (B) connector of the last server. Refer to the following illustration to see how to connect the ASM bus. Ethernet cable with RJ-45 connectors RS-485(A) RS-485(B) RS-485(A)
1. Turn on all the servers and the monitor and verify that the light in the Select button on server 1 in the C2T chain is lit, indicating that it is selected. If it is not, press the Select button. 2. Verify that the monitor is working. Hardware Maintenance Manual: xSeries 330 Type 8675...
3. Start up an operating system that has a mouse or pointing device driver and verify that the mouse or pointing device buttons function. 4. Test your keyboard by typing a few words within an application. 5. Press NumLock on the keyboard twice, and then press the number of the server to test next, and then press Enter.
Cable management Use the cable ties and hook-and-loop straps that are supplied with your server to secure the cables. Note: Do not secure cables too tightly. Overtightening can cause internal damage to cables. Hardware Maintenance Manual: xSeries 330 Type 8675...
Hard disk drive backplane To remove the hard disk drive backplane: Notes: 1. Read“Safety information” on page 135 and “Before you begin” on page 48 1. Power off the server. 2. Remove the cover. See “Removing the cover” on page 51. 3.
6. Remove the memory modules. See “Installing memory” on page 86. 7. Remove screws from the system board. 8. Remove the four screws from the rear of the server. 9. Pull up on the system board to remove from the chassis. Hardware Maintenance Manual: xSeries 330 Type 8675...
Symptom-to-FRU index This index supports xSeries 330 servers. The Symptom-to-FRU lists symptoms, errors, and the possible causes. The most likely cause is listed first. Use this Symptom-to-FRU index to help you decide which FRUs to have available when servicing the computer.
Page 118
3-2-4 (Failure comparing CMOS 1. DIMM memory size against actual) 2. System Board 3. Battery 3-3-1 (Memory size mismatch 1. DIMM Board occurred; see ″Memory Settings″ on 2. System Board page 34) 3. Battery Hardware Maintenance Manual: xSeries 330 Type 8675...
Beep/Symptom FRU/Action 3-3-2 (Critical SMBUS error 1. Disconnect the server power cord from outlet, wait 30 seconds and retry. occurred) 2. System Board 3. DIMMs 4. DASD Backplane 5. DASD Power Cable 3-3-3 (No operational memory in 1. Install or reseat the memory modules, then do a 3 boot reset. (See system) “Using the Configuration/Setup Utility program”...
Page 120
3) System Board d. System over recommended temperature for CPU X (where X is CPU number,) (CPU LED also on) 1) CPU X 2) System Board e. System Board over recommended temperature 1) System Board. Hardware Maintenance Manual: xSeries 330 Type 8675...
Diagnostic error codes Note: In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU. The description for these error codes are: The test passed. The Esc key was pressed to abort the test. This is a warning error and may not indicate a hardware failure.
Page 122
201-XXX-0NN (Failed Memory test, see 1. DIMM Location slots 1-4 where NN = DIMM location. ″Memory Settings″ on page 34) Note: NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN 4=DIMM 4 2. System Board Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 123
Error Code/Symptom FRU/Action 201-XXX-999 (Multiple DIMM failure, see 1. See error text for failing DIMMs error text) 2. System Board 202-XXX-001 (Failed System Cache test) 1. Microprocessor 1 2. System Board 202-XXX-002 (Failed System Cache test) 1. Microprocessor 2 2. System Board 206-XXX-000 (Failed Diskette Drive test) 1.
3) the drive you removed. Hang during Fixed Disk diagnostic 1. Remove the hardfile being tested at the time of the hang. Rerun the diagnostic. If successful, replace the drive you removed. Hardware Maintenance Manual: xSeries 330 Type 8675...
Error Symptom FRU/Action Not all drives are recognized by fixed 1. Remove first drive that does not show up and rerun diagnostic. If disk diagnostic. remaining drives show up, replace the one that was removed. 2. If remaining drives do not show up, remove successive drives one at a time and rerun diagnostic.
Page 126
602 (Invalid diskette boot record) 1. Diskette 2. Diskette Drive 3. Cable 4. System Board 604 (Diskette drive error) 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 127
Error Code/Symptom FRU/Action 605 (Unlock failure) 1. Diskette Drive 2. Drive Cable 3. System Board 662 (Diskette drive configuration error) 1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board 11XX (System board serial port 1 or 2 1.
Page 128
2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board 00180700, 00180800 (General PCI error) 1. System Board 2. PCI Card 01295085 (ECC checking hardware test 1. System Board. error) 2. Processor Hardware Maintenance Manual: xSeries 330 Type 8675...
Error Code/Symptom FRU/Action 01298001 (No update data for processor 1) 1. Ensure all processors are the same stepping level and cache size. 2. Processor 1 01298002 (No update data for processor 2) 1. Ensure all processors are the same stepping level and cache size. 2.
System shutoff due to CPU ″X″ under 1. Ambient temperature must be within normal operating temperature (level-critical; CPU ″X″ is under specifications, see “Features and specifications” on page 6. temperature) 2. Replace CPU ″X″ Hardware Maintenance Manual: xSeries 330 Type 8675...
Message Action System shutoff due to DASD temperature 1. Ensure system is being properly cooled, see “Temperature (sensor X) (level-critical; DASD area checkout” on page 29. reported temperature outside recommended 2. Replace SCSI Backplane operating range) System shutoff due to high ambient 1.
System Board. 2. If you suspect a networking problem and all the system tests pass, suspect a network cabling problem external to the system. Hardware Maintenance Manual: xSeries 330 Type 8675...
330 The xSeries 330 parts listing supports Type 8675 Index xSeries 330 Type 8675 (Model 4MX) FRU Number Heatsink/Clip Assembly 24P0653 Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 135
Index xSeries 330 Type 8675 (Model 4MX) FRU Number 133/1.4 GHz - 512K Intel Processor 48P7475 Fan with Connector (2) 00N6991 Fan with Connector (4) 24P1102 3.5-in. Floppy Disk Drive, 12.7MM 36L8645 Floppy Disk Drive/CD Bracket 00N6999 CD-ROM Drive, 24X LG (Primary)
Keyboard FRU No. Thailand 37L2587 French Canadian 37L0913 Power cords Power cord FRU No. China (PRC) 01K9851 Japan 01K9853 Thailand 12J5120 Israel 12J5122 Bangladesh, Burma, India, Pakistan, South Africa, Sri Lanka 12J5124 Chile, Ethiopia, Italy, Libya, Somalia 12J5126 Argentina, Australia, New Zealand, Papua New Guinea, Paraguay, 12J5128 Uruguay, Western Samoa Antigua, Bahrain, Brunei, Channel Islands, Cyprus, Dubai, Fiji,...
Page 138
Hardware Maintenance Manual: xSeries 330 Type 8675...
Safety information The following section contains the safety information that you need to be familiar with before servicing an IBM mobile computer. General safety Follow these rules to ensure general safety: v Observe good housekeeping in the area of the machines during and after maintenance.
– When using testers, set the controls correctly and use the approved probe leads and accessories for that tester. – Stand on suitable rubber mats (obtained locally, if necessary) to insulate you from grounds such as metal floor strips and machine frames. Hardware Maintenance Manual: xSeries 330 Type 8675...
This guide addresses only those items. However, good judgment should be used to identify potential safety hazards due to attachment of non-IBM features or options not covered by this inspection guide.
Insulation must not be frayed or worn. 4. Remove the cover. 5. Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations. 6. Check inside the unit for any obvious unsafe conditions, such as metal filings, contamination, water or other liquids, or signs of fire or smoke damage.
Italian v Korean v Spanish Important: All caution and danger statements in this IBM documentation begin with a number. This number is used to cross reference an English caution or danger statement with translated versions of the caution or danger statement in this section.
Page 144
Statement 2 CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
Page 145
18 kg (37 lbs) 32 kg (70.5 lbs) 55 kg (121.2 lbs) CAUTION: Use safe practices when lifting. v Statement 5 CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord.
Page 146
Importante: Todas as instruções de cuidado e perigo da IBM documentation começam com um número. Este número é utilizado para fazer referência cruzada de uma instrução de cuidado ou perigo no idioma inglês com as versões traduzidas das instruções de cuidado ou perigo encontradas nesta seção.
Page 147
Instrução 2 CUIDADO: Ao substituir a bateria de lítio, utilize apenas uma bateria IBM, Número de Peça 33F8354 ou uma bateria de tipo equivalente, recomendada pelo fabricante. Se o seu sistema possui um móídulo com uma bateria de lítio, substitua-o apenas pelo mesmo tipo de mídulo, do mesmo fabricante.
Page 148
CUIDADO: Instrução 10 CUIDADO: Não coloque nenhum objeto com peso superior a 82 kg (180 lbs.) sobre dispositivos montados em rack. Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 156
Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 157
Important: Toutes les consignes Attention et Danger indiquées dans la bibliothèque IBM documentation sont précédées d’un numéro. Ce dernier permet de mettre en correspondance la consigne en anglais avec ses versions traduites dans la présente section. Par exemple, si une consigne de type Attention est précédée du chiffre 1, ses traductions sont également précédées du chiffre 1 dans la présente section.
Page 158
ATTENTION: Remplacez la pile au lithium usagée par une pile de référence identique exclusivement - voir la référence IBM - ou par une pile équivalente recommandée par le fabricant. Si votre système est doté d’un module contenant une pile au lithium, vous devez le remplacer uniquement par un module identique, produit par le même fabricant.
Page 159
18 kg (37 lbs) 32 kg (70.5 lbs) 55 kg (121.2 lbs) ATTENTION: Faites-vous aider pour soulever ce produit. Notice n 5 ATTENTION: Le bouton de mise sous tension/hors tension de l’unité et l’interrupteur d’alimentation du bloc d’alimentation ne coupent pas l’arrivée de courant électrique à...
Page 160
Wichtig: Alle Sicherheitshinweise in dieser IBM documentation beginnen mit einer Nummer. Diese Nummer verweist auf einen englischen Sicherheitshinweis mit den übersetzten Versionen dieses Hinweises in diesem Abschnitt. Wenn z. B. ein Sicherheitshinweis mit der Nummer 1 beginnt, so erscheint die übersetzung für diesen Sicherheitshinweis in diesem Abschnitt unter dem Hinweis...
Page 161
Hinweis 2 ACHTUNG: Eine verbrauchte Batterie nur durch eine Batterie mit der IBM Teilenummer 33F8354 oder durch eine vom Hersteller empfohlene Batterie ersetzen. Wenn Ihr System ein Modul mit einer Lithium-Batterie enthält, ersetzen Sie es immer mit dem selben Modultyp vom selben Hersteller. Die Batterie enthält Lithium und kann bei unsachgemäßer Verwendung, Handhabung oder Entsorgung explodieren.
Page 162
Der Server könnte auch mehr als ein Netzkabel aufweisen. Um die gesamte Stromversorgung des Servers auszuschalten, muß sichergestellt werden, daß alle Netzkabel aus den Netzsteckdosen herausgezogen wurden. Hinweis 10 ACHTUNG: Keine Gegenstände, die mehr als 82 kg wiegen, auf Rack-Einheiten ablegen. Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 163
Importante: Tutti gli avvisi di attenzione e di pericolo riportati nella pubblicazione IBM documentation iniziano con un numero. Questo numero viene utilizzato per confrontare avvisi di attenzione o di pericolo in inglese con le versioni tradotte riportate in questa sezione.
Page 164
Avviso 2 ATTENZIONE: Quando si sostituisce la batteria al litio, utilizzare solo una batteria IBM con numero parte 33F8354 o batterie dello stesso tipo o di tipo equivalente consigliate dal produttore. Se il sistema di cui si dispone è provvisto di un modulo contenente una batteria al litio, sostituire tale batteria solo con un tipo di modulo uguale a quello fornito dal produttore.
Page 165
18 kg 32 kg 55 kg ATTENZIONE: Durante il sollevamento della macchina seguire delle norme di sicurezza. Avviso 5 ATTENZIONE: Il pulsante del controllo dell’alimentazione situato sull’unità e l’interruttore di alimentazione posto sull’alimentatore non disattiva la corrente elettrica fornita all’unità. L’unità potrebbe disporre di più di un cavo di alimentazione. Per disattivare la corrente elettrica dall’unità, accertarsi che tutti i cavi di alimentazione siano scollegati dalla sorgente di alimentazione.
Page 166
Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 168
Hardware Maintenance Manual: xSeries 330 Type 8675...
Page 169
Importante: Todas las declaraciones de precauciín de esta IBM documentation empiezan con un número. Dicho número se emplea para establecer una referencia cruzada de una declaraciín de precauciín o peligro en inglés con las versiones traducidas que de dichas declaraciones pueden encontrarse en esta secciín.
Page 170
PRECAUCIÓN: Cuando desee sustituir la batería de litio, utilice únicamente el número de pieza 33F8354 de IBM o cualquier tipo de batería equivalente que recomiende el fabricante. Si el sistema tiene un mídulo que contiene una batería de litio, sustitúyalo únicamente por el mismo tipo de mídulo, que ha de estar creado por el mismo fabricante.
Page 171
Declaración 4 18 kg 32 kg 55 kg PRECAUCIÓN: Tome medidas de seguridad al levantar el producto. Declaración 5 PRECAUCIÓN: El botín de control de alimentaciín del dispositivo y el interruptor de alimentaciín de la fuente de alimentaciín no apagan la corriente eléctrica suministrada al dispositivo.
We want to know your opinion about this manual (part number 24P2932). Your input will help us to improve our publications. Please photocopy this survey, complete it, and then fax it to IBM HMM Survey at 919-543-8167 (USA). Name: _________________________________________...
IBM intends to make these available in all countries in which IBM operates. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Subject to IBM’s valid intellectual property or other legally protectable rights, any...
Trademarks The following terms are trademarks of the IBM Corporation in the United States, other countries, or both: Active memory Predictive Failure Analysis Chipkill ServeRAID EtherJet ServerGuide e-business logo ServerProven HelpCenter Wake on LAN HelpWare X-Architecture xSeries Light Path Diagnostics Lotus and Domino are trademarks of Lotus Development Corporation and/or IBM Corporation in the United States, other countries, or both.