Table 18. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Error code
BA278007
BA278009
BA27800A
BA280000
BA290000
BA290001
BA290002
BA310010
92
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Description
Failed to reboot the system after a
firmware flash update
The operating system's server firmware
update management tools are
incompatible with this system.
The firmware installation failed due to a
hardware error that was reported.
RTAS discovered an invalid operation
that may cause a hardware error
RTAS discovered an internal stack
overflow
RTAS low memory corruption was
detected
RTAS low memory corruption was
detected
Unable to obtain the SRC history
Action
Restart the blade server.
Go to the IBM download site at
www14.software.ibm.com/webapp/set2/sas/
f/lopdiags/home.html to download the latest
version of the service aids package for Linux.
1. Look for hardware errors in the event log.
2. Resolve any hardware errors that are found.
3. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.

Advertisement