Table 27. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
268B-132
268B
268B-134
252B
Software
268B-135
268B
252B
Software
268B-136
268B
268B-137
268B
252B
268B-138
268B
268B-140
199
252B
268B
156
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Description and Action
A disk drive hardware error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the Tier 2
system-board and chassis assembly.
The adapter failed to configure.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the Tier 2
system-board and chassis assembly.
The device failed to configure.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the Tier 2
system-board and chassis assembly.
The certify operation failed.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the Tier 2
system-board and chassis assembly.
Unit attention condition has occurred on the Send Diagnostic command.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the Tier 2
system-board and chassis assembly.
Error log analysis indicates that the disk drive is operating at a higher than
recommended temperature.
v Make sure that:
– The ventilation holes in the blade server bezel are not blocked.
– The management-module event log is not reporting any system environmental
warnings.
v If the problem remains, call IBM support.
Error log analysis indicates poor signal quality.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in Replacing the Tier 2
system-board and chassis assembly.