E15 SPRAYER- Alarm Messages
10.2 ALARM MESSAGES
LOW SPEED SHUTOFF-
detected, or the ground speed is below the value set in the LOW SPEED SHUTOFF
(See Section 3.5 to set). The boomspray will not spray when this alarm is
displayed.
To rectify the problem drive
MIN FLOW ALARM
- This alarm will be displayed when the flow going through
the flowmeter is below the value set in the MINIMUM FLOW (See section 1.1.3 to
set) and see (Section 4.1.1 to turn the alarm ON or OFF). Every flowmeter has a
minimum rate that it can control to accurately, the MINIMUM FLOW should be
set at that value, see manufacturers specifications.
To rectify the problem drive
RATE LOW ALARM-
applied is below the target rate the operator has selected. The alarm point is set
as a percentage(%) see (Section 4.1.3 to set the ALARM POINT and see Section
4.1.2 to switch the RATE LOW ALARM, ON or OFF). Therefore if the the ALARM
POINT is set a 10% and the target rate is 50L/HA, then the RATE LOW ALARM
will be displayed when actual rate falls below 45L/HA.
If a RATE LOW ALARM is displayed drive
RATE HIGH ALARM-
applied is higher than target rate the operator has selected. The alarm point is
set as a percentage(%) see (Section 4.1.5 to set the ALARM POINT and Section
4.1.4 to switch the RATE HIGH ALARM, ON or OFF). Therefore if the the ALARM
POINT is set a 10% and the target rate is 50L/HA, then the RATE HIGH ALARM
will be displayed when actual rate is greater than 55L/HA.
If a RATE HIGH ALARM is displayed drive
MANUAL SPEED ENABLED-
SPEED has been enabled, and no ground speed is detected. As soon as a ground
speed is detected then the alarm will disappear.(See Section 3.10 to set MANUAL
SPEED)
PRESSURE 1 LOW-
When a Pressure Sensor is installed in the system and the
pressure falls below the PRESSURE LOW ALARM point, a PRESSURE 1 LOW alarm
is displayed.The PRESSURE LOW ALARM POINT is usually set at the lowest
operating range of the nozzles.The ALARM POINT is set in section 4.5.2.
To rectify the problem drive
PRESSURE 1 HIGH-
When a Pressure Sensor is installed in the system and the
pressure is higher than the PRESSURE HIGH ALARM point, a PRESSURE 1 HIGH
alarm is displayed.The PRESSURE HIGH ALARM POINT is usually set at the highest
operating range of the nozzles.The ALARM POINT is set in section 4.5.4.
To rectify the problem drive
This alarm will come when no ground speed has been
faster.
faster.
This alarm will be displayed when the actual rate being
This alarm will be displayed when the actual rate being
This alarm will be displayed when the MANUAL
faster.
slower.
faster
to rectify the problem
slower
to rectify the problem.