E15h SPRAYER- Configuration Option
8.2.1 Alarm Beeper Overview-
• This screen allows to change the settings on how the alarm will beep when an
alarm appears in the ALARM WINDOW on the Working Screen.
• The ALARM CYCLE TIME sets how long in milliseconds(mS) the alarm stays
in the ALARM WINDOW.
• The ALARM CYCLES is how many times the alarm will cycle (beep and flash, in the
'Alarm Window'
• The ALARM DUTY CYCLE is the percentage of time the beeper will beep, when the
alarm is flashing in the 'Alarm Window'. Ie. When the ALARM DUTY CYCLE is set
at 50% the beep will sound for half the time (50%), the alarm flashes in the
'Alarm Window.' The ALARM BEEPER needs to be switched ON.
• The ALARM BEEPER can be switched ON or OFF. When the beeper is turned ON,
the console will beep as well as display what the alarm is. When the beeper is
turned OFF, the alarm will be displayed on the screen but without the beep
• Ie. The default settings are displayed on the screen, see Section 12.2.
• The alarm will appear in the ALARM WINDOW.
• The alarm will flash for 1 second.
• The alarm will beep for 1/2 a second (50% of the alarm cycle time), and the alarm
will cycle (flash and beep) 5 times.
• After the 5 cycles the beep will stop and if the alarm is still present, then the alarm
will cycle through in the ALARM WINDOW with no beep.
V 1.0 11/05
81