v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the Problem Determination and Service Guide on the IBM System x Documentation CD to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
1810
PCI error.
01295085
ECC checking hardware test error.
01298001
No update data for processor 1.
01298002
No update data for processor 2.
74
IBM System x3500 Type 7977: Installation Guide
Action
1. Make sure that no devices have been disabled in
the Configuration/Setup Utility program.
2. Reseat the failing adapter.
Note: If an error LED is lit for a specific adapter,
reseat that adapter first; if no LEDs are lit, reseat
each adapter one at a time, restarting the server
each time, to isolate the failing adapter.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Each adapter
b. (Trained service technician only) PCI-X board
1. Reseat the following components:
a. DIMM
b. (Trained service technician only)
Microprocessor
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor
b. DIMM
c. (Trained service technician only) System
board
1. Make sure that all microprocessors have the
same cache size (see the Problem Determination
and Service Guide on the IBM System x
Documentation CD).
2. Update the BIOS code.
3. (Trained service technician only) Reseat
microprocessor 1.
4. (Trained service technician only) Replace
microprocessor 1.
1. Make sure that all microprocessors have the
same cache size (see the Problem Determination
and Service Guide on the IBM System x
Documentation CD).
2. Update the BIOS code again (see the Problem
Determination and Service Guide on the IBM
System x Documentation CD).
3. (Trained service technician only) Reseat
microprocessor 2.
4. (Trained service technician only) Replace
microprocessor 2.