Page 8
Each caution and danger statement in this document is labeled with a number. This number is used to cross reference an English-language caution or danger statement with translated versions of the caution or danger statement in the IBM Safety Information book.
Page 9
Statement 1: DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet.
Page 10
Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
Page 11
Statement 3: CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following: v Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.
Page 12
The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. IBM System x3500 Type 7977: User’s Guide...
Page 13
Statement 8: CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components.
Page 14
IBM System x3500 Type 7977: User’s Guide...
Safety Information This document is in PDF on the IBM System x Documentation CD. It contains translated caution and danger statements. Each caution and danger statement that appears in the documentation has a number that you can use to locate the corresponding statement in your language in the Safety Information document.
Features and specifications The following information is a summary of the features and specifications of the server. Depending on the server model, some features might not be available, or some specifications might not apply. Table 1. Features and specifications Microprocessor: Hot-swap fans: Acoustical noise emissions: ®...
LEDs to help you diagnose the problem. v Device Driver and IBM Enhanced Diagnostics CD The server comes with a Device Driver and IBM Enhanced Diagnostics CD, which you can use to diagnose problems. v IBM Director IBM Director is a workgroup-hardware-management tool that you can use to ®...
v Online-spare memory Online-spare memory disables a failed rank pair of DIMMs from the system configuration and activates an online-spare rank pair of DIMMs to replace the failed rank pair of DIMMs. For an online-spare pair of DIMMs to be activated, you must enable this feature and have installed an additional pair of DIMMs of the same speed, type, size (or larger), and technology as the failed pair of DIMMs.
Hot-swap SAS hard disk drives v Integrated Ethernet controllers v Intelligent Platform Management Interface (IPMI) 2.0 v Support for the optional IBM Remote Supervisor Adapter II SlimLine v Key-lock support for physical security v Memory change messages posted to the error log v Power-on self-test (POST) ®...
Reduced service and support costs For more information about IBM Director, see the documentation on the IBM Director CD that comes with the server, the IBM Director Information Center at http://publib.boulder.ibm.com/infocenter/eserver/v1r2/topic/diricinfo_all/ diicinfoparent.html, and the IBM System x Systems Management Web page at http://www.ibm.com/systems/management/, which presents an overview of IBM...
The event is recorded in the error log. Check the light path diagnostic panel for more information (see the Problem Determination and Service Guide on the IBM System x Documentation CD).
Page 23
LED. When this LED is lit, it indicates that the drive has failed. If an optional IBM ServeRAID controller is installed in the server, when this LED is flashing slowly (one flash per second), it indicates that the drive is being rebuilt.
Serial 2 (COM 2) connector: Connect a 9-pin serial device to this connector. This connector can also be redirected in the Configuration/Setup Utility program for use with the baseboard management controller (BMC) or Remote Supervisor Adapter II IBM System x3500 Type 7977: User’s Guide...
SlimLine to control the server remotely. Do not connect any 9-pin serial devices to this connector when it is configured for use with the BMC or Remote Supervisor Adapter II SlimLine. Note: When this connector is configured for use with the system management, do not connect any other 9-pin serial devices to this connector.
Page 26
The integrated system management processor can turn off the server as an automatic response to a critical system failure. v You can turn off the server through a request from the service processor. IBM System x3500 Type 7977: User’s Guide...
Boot block: v Leave the switch in the off position for normal mode. v Move the switch to the on position to enable the system to recover if the BIOS code becomes damaged. IBM System x3500 Type 7977: User’s Guide...
Table 2. Switches on SW4 (continued) Switch number Description Clear CMOS: v Leave the switch in the off position to keep the CMOS data. v Move the switch to the on position to clear the CMOS data, which clears the power-on password and administrator password.
For more information about light path diagnostics, see the Problem Determination and Service Guide on the IBM System x Documentation CD. The following table lists the light path diagnostics LEDs, the problems that they indicate, and actions to solve the problems.
Page 31
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the Problem Determination and Service Guide on the IBM System x Documentation CDto determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 32
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the Problem Determination and Service Guide on the IBM System x Documentation CDto determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 33
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the Problem Determination and Service Guide on the IBM System x Documentation CDto determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
Page 34
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See the Problem Determination and Service Guide on the IBM System x Documentation CDto determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
If the server is not working correctly, see the Problem Determination and Service Guide on the IBM System x Documentation CD for information on how to run diagnostics.
For a list of supported optional devices for the server, see http://www.ibm.com/ servers/eserver/serverproven/compat/us/. System reliability guidelines To help ensure proper cooling and system reliability, make sure that the following requirements are met: v Each of the drive bays has a drive or an electromagnetic compatibility (EMC) shield installed in it.
v Handle the device carefully, holding it by its edges or its frame. v Do not touch solder joints, pins, or exposed circuitry. v Do not leave the device where others can handle and damage it. v While the device is still in its static-protective package, touch it to an unpainted metal part of the server for at least 2 seconds.
Avoid touching the components and gold-edge connectors on the adapter. v PCI slot 6 supports half-length 5.0 V PCI adapters only. v PCI slot 1 supports half-length 3.3 V PCI adapters only. IBM System x3500 Type 7977: User’s Guide...
Page 39
v PCI slots 2 through 5 support full-length 3.3 V signaling adapters only. v The PCI configuration: – Slot 1 is a PCI Express x8 slot with x4 links, PCI Express 1.0a compliant. – Slot 2 and 3 are PCI Express x8 slots with x8 links, PCI Express 1.0a compliant.
Page 40
Attention: Incomplete insertion might cause damage to the system board or the adapter. 8. Connect any needed cables to the adapter. IBM System x3500 Type 7977: User’s Guide...
If you have other optional devices to install or remove, do so now. Otherwise, go to “Completing the installation” on page 46. Installing a DVD drive Optical drive To remove a DVD drive, complete the following steps: 1. Read the safety information that begins on page v and “Installation guidelines” on page 21.
8. Replace the left-side cover and bezel; then, lock the side cover and bezel. 9. Reconnect the external cables and power cords. If you have other optional devices to install or remove, do so now. Otherwise, go to “Completing the installation” on page 46. IBM System x3500 Type 7977: User’s Guide...
Installing a USB tape drive EMC shields Tape drive To install a USB tape drive, complete the following steps: 1. Read the safety information that begins on page v and “Installation guidelines” on page 21. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables necessary to replace the device.
0 through 7 (from top to bottom) on models with eight hard disk drives and 0 through 11 (from top to bottom) on models with 12 hard disks. v For a list of supported optional devices for the server, see http://www.ibm.com/ servers/eserver/serverproven/compat/us/.
“Completing the installation” on page 46. Installing an IBM Remote Supervisor Adapter II SlimLine An optional IBM Remote Supervisor Adapter II SlimLine can be installed only in its dedicated connector on the system board. The Remote Supervisor Adapter II SlimLine is not cabled to the system board.
Page 46
Remote Supervisor Adapter II SlimLine 5. Open the rear adapter retention bracket and install the Remote Supervisor Adapter II SlimLine retention tab on the bracket by clipping it onto the rear adapter retention bracket. IBM System x3500 Type 7977: User’s Guide...
5300 SDRAM Fully Buffered DIMM (FBD) specification. For a list of supported optional devices for the server, see http://www.ibm.com/servers/eserver/serverproven/compat/us/. v At least one pair of DIMMs must be installed for the server to operate. Chapter 2. Installing optional devices...
Page 48
(for example, DIMM connector 1 and DIMM connector 4) within the channels of a branch must be identical in size, type, speed, and technology. However, the DIMMs in the connectors above or below each IBM System x3500 Type 7977: User’s Guide...
Page 49
other within the channels of a branch do not have to be identical to each other (for example, the DIMMs in DIMM connector 1 and DIMM connector - Both branches operate in dual-channel mode. The following table shows the DIMM configuration upgrade sequence for operating in mirroring mode.
Page 50
– DIMMs must be installed in matched pairs. If you install a second pair of DIMMs in DIMM connector 7 and DIMM connector 10, they do not have to be the same size, speed, type, and technology as the DIMMs in DIMM connector IBM System x3500 Type 7977: User’s Guide...
Page 51
1 and DIMM connector 4. However, the size, speed, type, and technology of the DIMMs that you install in DIMM connector 7 and DIMM connector 10 must match each other. – The following table shows the DIMM upgrade configuration sequence for operating in non-mirroring mode (normal mode).
Page 52
1. Read the safety information that begins on page v and “Installation guidelines” on page 21. 2. Turn off the server and peripheral devices; then, disconnect the power cords and all external cables. Remove the cover. IBM System x3500 Type 7977: User’s Guide...
The following notes describe the type of microprocessor that the server supports and other information that you must consider when you install a microprocessor: v For a list of supported optional devices for the server, go to http://www.ibm.com/ us/compat/. v The server supports Intel Xeon dual-core or quad-core 1.6 GHz or higher microprocessors in each socket.
Page 54
Also, contaminants on the microprocessor contacts, such as oil from your skin, can cause connection failures between the contacts and the socket. 6. Install the microprocessor by using the vacuum tool and completing the following steps. IBM System x3500 Type 7977: User’s Guide...
Page 55
Vacuum tool Microprocessor Socket a. Squeeze and hold the bladder of the tool; then, place the suction cup on the microprocessor and release the bladder. Note: To maintain proper orientation between the microprocessor and the microprocessor socket during installation, observe the following information: v The microprocessor has two notches that are keyed to two tabs on the sides of the socket.
21. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables. Remove the left-side cover. 3. Remove all adapters. Fan air baffle Hot-swap fan IBM System x3500 Type 7977: User’s Guide...
Page 57
4. Remove the fan air baffle from the fan cage assembly by pushing in on the tab on the back of the air baffle; then, push the baffle to the left and lift it out of the fan cage assembly. 5.
Page 58
Position the transition duct so that the two tabs are directly over the slots on the side of the DIMM air baffle. d. Slide the transition duct into the slots until it clicks into place. 9. Reinstall the DIMM air baffle onto the power-supply cage. IBM System x3500 Type 7977: User’s Guide...
Page 59
Power supply support bracket Power supply release tab 10. Raise the power-supply cage slightly and press and hold the release tab on the rear power-supply support bracket; then, lower the power-supply structure into position. For clarity, the power-supply cage is not shown in the illustration. Rear fan assembly with baffle 11.
4. Rotate the top edge of left-side cover toward the server; then, press down on the cover until it clicks into place. 5. Rotate the bezel to its fully closed position. 6. Using the supplied key, lock the left-side cover and bezel. IBM System x3500 Type 7977: User’s Guide...
7. Connect the cables and power cords. For more information, see “Connecting the cables.” Connecting the cables Notes: 1. Be sure to turn off the server before you connect any cables to or disconnect any cables from the server or hot-plug adapter. 2.
Page 62
Remote Supervisor Adapter User’s Guide, which comes with the adapter, for information about setting up, configuring, and using the adapter. For information about configuring the integrated Gigabit Ethernet controller, see “Configuring the Broadcom Gigabit Ethernet controller” on page 70. IBM System x3500 Type 7977: User’s Guide...
IBM Director IBM Director is a workgroup-hardware-management tool that you can use to centrally manage servers. If you plan to use IBM Director to manage the server, you must check for the latest applicable IBM Director updates and interim fixes.
For information about updating IBM Director, see “Updating IBM Director” on page 75. For more information about IBM Director, see the IBM Director documentation on the IBM Director CD. Using the Configuration/Setup Utility program Use the Configuration/Setup Utility program to perform the following tasks:...
Page 65
Attention: Do not make changes in the Advanced Chipset Control option unless you are directed to do so by an IBM authorized service representative. – Video Select this choice to view the video information.
Page 66
BMC system-event log is cleared. Disabled is the default setting. - Existing Event Log number This is a nonselectable menu item that displays the number of entries in the system-event log. IBM System x3500 Type 7977: User’s Guide...
Page 67
Select this choice to view the BMC system-event log, which contains all system error and warning messages that have been generated. Use the arrow keys to move among pages in the log. If an optional IBM Remote Supervisor Adapter II SlimLine is installed, the full text of the error messages is displayed;...
Start the Configuration/Setup Utility program and reset the power-on password. v Remove the server battery and then reinstall it. For instructions for removing the battery, see the Problem Determination and Service Guide on the IBM System x3500 Documentation CD. IBM System x3500 Type 7977: User’s Guide...
If a later version of the ServerGuide program is available, you can download a free image of the ServerGuide Setup and Installation CD or purchase the CD from the ServerGuide fulfillment Web site at http://www.ibm.com/systems/management/ serverguide/sub.html. To download the free image, click IBM Service and Support Site. Chapter 3. Configuring the server...
When you use the ServerGuide Setup and Installation CD, you do not need setup diskettes. You can use the CD to configure any supported IBM server model. The setup program provides a list of tasks that are required to set up the server model.
ServerGuide program to install your operating system, complete the following steps to download the latest operating-system installation instructions from the IBM Web site. Note: Changes are made periodically to the IBM Web site. The actual procedure might vary slightly from what is described in this document. 1. Go to http://www.ibm.com/systems/support/.
Complete the following steps to update and configure the BIOS code to enable SOL: 1. Update the BIOS code: a. Download the latest version of the BIOS code from http://www.ibm.com/ systems/support/. b. Update the BIOS code, following the instructions that come with the update file that you downloaded.
h. Select Save Settings; then, press Enter. i. Press Enter to confirm. j. Select Exit Setup; then, press Enter. k. Make sure that Yes, exit the Setup Utility is selected; then, press Enter. Linux configuration ® For SOL operation on the server, you must configure the Linux operating system to expose the Linux initialization (booting) process.
Page 74
The following examples show the original content of the /etc/lilo.conf file and the content of this file after modification. Original /etc/lilo.conf contents prompt timeout=50 default=linux boot=/dev/hda map=/boot/map install=/boot/boot.b message=/boot/message linear image=/boot/vmlinuz-2.4.9-e.12smp label=linux initrd=/boot/initrd-2.4.9-e.12smp.img read-only root=/dev/hda6 image=/boot/vmlinuz-2.4.9-e.12 label=linux-up initrd=/boot/initrd-2.4.9-e.12.img read-only root=/dev/hda6 IBM System x3500 Type 7977: User’s Guide...
Page 75
Modified /etc/lilo.conf contents prompt timeout=50 default=linux-Monitor boot=/dev/hda #map=/boot/map install=/boot/boot.b #message=/boot/message linear # This will allow you to only Monitor the OS boot via SOL image=/boot/vmlinuz-2.4.9-e.12smp label=linux-Monitor initrd=/boot/initrd-2.4.9-e.12smp.img read-only root=/dev/hda6 append="console=ttyS0,19200n8 console=tty1" # This will allow you to Interact with the OS boot via SOL image=/boot/vmlinuz-2.4.9-e.12smp label=linux-Interact initrd=/boot/initrd-2.4.9-e.12smp.img...
Page 76
Red Hat Enterprise Linux ES (2.4.9-e.12smp) root (hd0,0) kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 initrd /initrd-2.4.9-e.12smp.img title Red Hat Enterprise Linux ES-up (2.4.9-e.12) root (hd0,0) kernel /vmlinuz-2.4.9-e.12 ro root=/dev/hda6 initrd /initrd-2.4.9-e.12.img IBM System x3500 Type 7977: User’s Guide...
Page 77
Modified /boot/grub/grub.conf contents #grub.conf generated by anaconda # Note that you do not have to rerun grub after making changes to this file # NOTICE: You have a /boot partition. This means that all kernel and initrd paths are relative to /boot/, eg. root (hd0,0) kernel /vmlinuz-version ro root=/dev/hda6 initrd /initrd-version.img...
Page 78
(hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 console=ttyS1,19200 console=tty1 initrd (hd0,1)/boot/initrd # This will allow you to Interact with the OS boot via SOL title linux SOL Interactive kernel (hd0,1)/boot/vmlinuz root=/dev/hda2 acpi=oldboot vga=791 console=tty1 console=ttyS0,19200 initrd (hd0,1)/boot/initrd title floppy IBM System x3500 Type 7977: User’s Guide...
Modified /boot/grub/menu.lst contents Notes root chainloader +1 title failsafe kernel (hd0,1)/boot/vmlinuz.shipped root=/dev/hda2 ide=nodma apm=off vga=normal nosmp disableapic maxcpus=0 3 initrd (hd0,1)/boot/initrd.shipped Note 1: The kernel line is shown with a line break. In your file, the entire entry must all be on one line. You must restart the Linux operating system after you complete these procedures for the changes to take effect and to enable SOL.
Complete the following steps to install the OSA SMBridge management utility program on a server running a Windows operating system: 1. Go to http://www.ibm.com/systems/support/, download the utility program, and create the OSA BMC Management Utility CD. 2. Insert the OSA BMC Management Utility CD into the drive. The InstallShield wizard starts, and a window similar to that shown in the following illustration opens.
Page 81
Linux operating system. You must be logged in as a root user to perform these procedures. 1. Go to http://www.ibm.com/systems/support/, download the utility program, and create the OSA BMC Management Utility CD. 2. Insert the OSA BMC Management Utility CD into the drive.
Use the following commands in CLI mode: – identify Control the system-locator LED on the front of the server. – power Turn the server on and off remotely. – sel Perform operations with the BMC system event log. IBM System x3500 Type 7977: User’s Guide...
– sysinfo Display general system information that is related to the server and the baseboard management controller. v Serial over LAN Use the Serial over LAN capability to remotely perform control and management functions over a Serial over LAN (SOL) network. You can also use SOL to remotely view and change the server BIOS settings.
To find updated information about configuring the controller, complete the following steps. Note: Changes are made periodically to the IBM Web site. The actual procedure might vary slightly from what is described in this document. 1. Go to http://www.ibm.com/systems/support/.
(MIB) on your SNMP manager. v You will need an Internet connection to the client system to download software and firmware from the IBM Support Web site during the installation process. The Remote Supervisor Adapter II SlimLine firmware and the SNMP MIB are available on the ServerGuide Setup and Installation CD;...
8. Restart the server after the software and firmware are installed. Completing the setup See the IBM Remote Supervisor Adapter II SlimLine User’s Guide on the IBM Documentation CD for instructions for completing the configuration, including the following procedures:...
5. To exit from the program, press Esc. Using ServeRAID Manager Use ServeRAID Manager, which is on the IBM ServeRAID Support CD, to: v Configure a redundant array of independent disks (RAID) array v Restore a SAS hard disk drive to the factory-default settings, erasing all data...
SAS settings for attached devices. See the ServeRAID documentation on the IBM ServeRAID Support CD for additional information about RAID technology and instructions for using ServeRAID Manager to configure your SAS and RAID controllers. Additional information about ServeRAID Manager is also available from the Help menu.
Actions. Updating IBM Director If you plan to use IBM Director to manage the server, you must check for the latest applicable IBM Director updates and interim fixes. To install the IBM Director updates and any other applicable updates and interim fixes, complete the following steps.
Page 90
IBM System x3500 Type 7977: User’s Guide...
Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives that are available from IBM. Maximum memory might require replacement of the standard memory with an optional memory module.
IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software might differ from its retail version (if available) and might not include user manuals or all program functionality.
United States, go to http://www.ibm.com/ibm/environment/ products/index.shtml or contact your local waste disposal facility. In the United States, IBM has established a return process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment.
For proper collection and treatment, contact your local IBM representative. For California: Perchlorate material – special handling may apply. See http://www.dtsc.ca.gov/ hazardouswaste/perchlorate/.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
Telephone: 0049 (0)711 785 1176 Fax: 0049 (0)711 785 1283 E-mail: tjahn@de.ibm.com Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for Interference (VCCI) statement Appendix. Notices...
Page 98
IBM System x3500 Type 7977: User’s Guide...
5 danger statements 2 DASD LED 19 baseboard management controller utility programs 68 data rate, Ethernet 70 battery return program 80 Device Driver and IBM Enhanced Diagnostics CD 4 bays 3 device drivers 7 bezel diagnostics CD 4 removing 23...
Page 100
38 OSA SMBridge management utility program jumper enabling and configuring 58 power-on password override 55 installing 66 keyboard connector 10 parallel connector 10 password administrator 51, 54, 55 forgotten power-on 54 IBM System x3500 Type 7977: User’s Guide...
Page 101
password (continued) serial over LAN (continued) power on, override jumper 55 commands (continued) power-on 54 power 69 setting 51 reboot 69 using 54 sel get 69 sol 69 slot 1 25 sysinfo 69 slot 6 25 server components 13 slots 2 and 3 25 ServeRAID 5 slots 4 and 5 25 ServeRAID Manager 73...
Page 102
Adaptec RAID Configuration 72 video connector 10 viewing the configuration Configuration/Setup Utility 50 VRM installation 41 VRM LED 18 Web site ServerGuide 55 weight 3 working inside the server with the power on 22 IBM System x3500 Type 7977: User’s Guide...
Page 104