Determining the motor torque-speed diagram
If the motor torque-speed diagram is not available, then determine the motor torque-speed
diagram from the following data taken from the "Motor torque speed diagram" figure.
● Maximum torque M
● Rated torque M
In this diagram, transfer all operating points of the duty cycle from the motor torque-time
diagram and the speed-time diagram. Generally, you only have to search for critical points in
time in the torque-time diagram. Critical points in time are when the maximum speed
exceeds the n
For these points in time, determine the motor torque (in the example M
torque-time diagram. Check whether the motor torque lies below the characteristic in the
motor torque-speed diagram.
Figure 5-6
Naturally cooled 1FW6 built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE01-0BP3
with the associated speed n
MAX
with the associated speed n
N
at peak torque.
MAX,MMAX
Motor torque-time diagram and associated speed-time diagram
5.2 Configuring workflow
MAX,MMAX