Siemens SIMOTICS T-1FW6 Series Configuration Manual page 82

Naturally cooled built-in torgue motors for sinamics s120
Hide thumbs Also See for SIMOTICS T-1FW6 Series:
Table of Contents

Advertisement

Configuration
5.2 Configuring workflow
In addition to the peak torque M
decisive factor when dimensioning the motor. The rms torque M
temperature rise in the motor can be derived from the motor torque-time diagram by means
of quadratic averaging (root mean square) and must not exceed the rated torque M
If the individual torques are stable in each section, the integral can be simplified to create a
totals formula (see also the following diagram).
Figure 5-4
80
mMAX
Motor torque-time diagram
, the required rms torque M
Naturally cooled 1FW6 built-in torque motors
Configuration Manual, 07/2017, 6SN1197-0AE01-0BP3
of the motor is also a
eff
mainly responsible for the
eff
.
N