Supply voltage
p0210
U_line supply calculated
p0281 (110 %)
[8950.4]
300 ms
p0282 (85 %)
Nominal line
Calculated
p0283 (75 %)
supply voltage
actual line
supply voltage
85 % 110 %
U_line supply after filter
[8960.6]
<1> For p3400.0 = 1, [8864] applies.
<2> Only when selecting an AIM (Active Interface Module) in p0220.
1
2
DO: A_INF
Active Infeed - Signals and monitoring functions, line supply voltage monitoring (p3400.0 = 0)
A06301
"Line supply overvoltage"
A06105
&
"Line supply undervoltage"
F06100
"Shutdown due to line supply undervoltage"
A06310
"Supply voltage (p0210) incorrectly parameterized"
3
4
Monitoring when switching-in the pulses
(regarding the frequency, refer to [8964])
U_line supply after filter
[8960.2]
Vdc_max stat
[8940.4]
Temperature monitor active interface module.
60 s
X21.1
X21.2
T
0
F06261
"Temperature in the line filter permanently too high"
F06260
"Temperature in the line filter too high"
5
6
Function diagram
fp_8960_01_eng.vsd
SINAMICS S
04.07.07 V02.05.00
p0115[3] (2000.00 µs)
<1>
A06300
"Line supply voltage too high when powering-up"
--> voltage cannot be controlled
Background
<2>
7
8
- 8960 -