Faults and Alarms
List of faults and alarms
A02150
OA: Application cannot be loaded
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
The system was not able to load an OA application.
Alarm value (r2124, interpret hexadecimal):
Only for internal Siemens troubleshooting.
Remedy:
- carry out a POWER ON (power off/on) for all components.
- upgrade the firmware release.
- contact the Hotline.
Note:
OA: Open Architecture
See also: r4950 (OA application count), r4955 (OA application identifier), p4956 (OA application activation), r4957
(OA application version)
F02151 (A)
OA: Internal software error
Drive object:
All objects
Reaction:
A_INFEED: OFF2 (NONE, OFF1)
SERVO: OFF2 (NONE, OFF1, OFF3)
VECTOR: OFF2 (NONE, OFF1, OFF3)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
An internal software error has occurred within an OA application.
Fault value (r0949, interpret hexadecimal):
Only for internal Siemens troubleshooting.
Remedy:
- carry out a POWER ON (power off/on) for all components.
- upgrade the firmware release.
- contact the Hotline.
- replace the Control Unit.
Note:
OA: Open Architecture
See also: r4950 (OA application count), r4955 (OA application identifier), p4956 (OA application activation), r4957
(OA application version)
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F02152 (A)
OA: Insufficient memory
Drive object:
All objects
Reaction:
OFF1
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
Too many functions have been configured on this Control Unit (e.g. too many drives, function modules, data sets,
OA applications, blocks, etc).
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy:
- change the configuration on this Control Unit (e.g. fewer drive, function modules, data sets, OA applications, blocks,
etc).
- use an additional Control Unit.
Note:
OA: Open Architecture
Reaction upon A:
NONE
Acknowl. upon A:
NONE