PLC and motion control performance
Table 4- 5
Data
Maximum number of
axes
Minimum
PROFIBUS cycle
Minimum PROFINET
transmission cycle
Minimum
servo/interpolator cycle
clock
Compared with SIMOTION D445, SIMOTION D445-1 offers an improvement in PLC and
motion control performance of approximately 30%, depending on the application.
Integrated drive control
Table 4- 6
Data
Max. number of axes
for integrated drive
control (servo / vector /
f
V/
Communication
Table 4- 7
Data
DRIVE-CLiQ interfaces
Ethernet ports
PROFIBUS interfaces
PROFINET interfaces
D4x5
Manual, 05/2009
Maximum number of axes and minimum cycles for D4x5
SIMOTION D425
16
2 ms
0.5 ms
2.0 ms
Controls for integrated drives
SIMOTION D425
6 / 4 / 8 (alternative)
)
Interface communication
SIMOTION D425
4
2
2
Optionally over CBE30:
SIMOTION D435
32
1 ms
0.5 ms
1.0 ms
SIMOTION D435
6 / 4 / 8 (alternative)
SIMOTION D435
4
2
2
Optionally over CBE30:
1 interface with 4
ports
Supports
PROFINET IO with
IRT and RT
Can be configured
as PROFINET IO
controller and/or
device
4.1 Technical data D4x5
SIMOTION
D445/D445-1
64
1 ms
0.5 ms
0.5 ms
SIMOTION
D445/D445-1
6 / 4 / 8 (alternative)
SIMOTION
D445/D445-1
6
2
2
Optionally over CBE30:
1 interface with 4
ports
Supports
PROFINET IO with
IRT and RT
Can be configured
as PROFINET IO
controller and/or
device
Technical Data
1 interface with 4
ports
Supports
PROFINET IO with
IRT and RT
Can be configured
as PROFINET IO
controller and/or
device
55