Installing
4.6 Installing Control Unit
4.6.7.1
PROFINET
You can either communicate via Ethernet using the inverter, or integrate the inverter in a
PROFINET network.
● The inverter as an Ethernet station (Page 451)
● PROFINET IO operation (Page 109)
In PROFINET IO operation, the inverter supports the following functions:
– RT
– IRT
– MRP
– MRPD
– Diagnostic alarm
– Device replacement without removable medium
– Shared device
108
The inverter transmits the clock synchronism but does not support clock synchronism.
Media redundancy, impulsed with 200 ms
Requirement: Ring topology
Media redundancy, impulse-free
Requirement: IRT and the ring topology created in the control
in accordance with the fault classes specified in the PROFIdrive profile. See Activating
diagnostics via the control (Page 111).
Requirement: Topology created in the control
only in the case of control units with fail-safe functions (see Safety function manual)
Converter with CU230P-2 Control Units
Operating Instructions, 04/2015, FW V4.7 SP3, A5E34257946B AB