Introduction

2.2 Navigator through the "Safety Integrated" Function Manual

2.2
Navigator through the "Safety Integrated" Function Manual
Chapter
Description (Page 21)
Installing (Page 45)
Commissioning
(Page 101)
Operation (Page 213)
Corrective maintenance
(Page 331)
18
You can find answers to the following questions in the chapter:
● What are basic functions and what are extended functions?
● Which safety functions does the inverter have?
● Which interfaces does the inverter have to select the safety functions?
● What preconditions, restrictions and recommendations apply when using the safety
functions?
● How do the safety functions basically work?
● Which sequence is recommended when installing the inverter?
● What options are available to connect the inverter to the higher-level control system
via PROFIsafe?
● How are the PROFIsafe control words and status words assigned?
● How do you wire the fail-safe digital inputs and outputs of the inverter?
● What differences are there when wiring inside and outside the control cabinet?
● How do you connect a monitored motor holding brake?
● Which sequence is recommended when commissioning the inverter?
● Which tool do you require for commissioning?
● How do you restore the factory setting of the safety functions?
● In SINAMICS G120, is it permissible to use the safety functions according to SIL 2
and SIL 3 together?
● How do you commission the safety functions?
● How do you configure communications via PROFIsafe in the inverter?
● How do you transfer safety function parameters to other inverters?
● Why is it necessary to "Accept safety functions"?
● What does accepting safety functions involve?
● How do you maintain the guaranteed probability of failure of the safety functions over
the mission time?
● How does the drive respond when selecting or deselecting a safety function?
● How do you switch on a motor with a safety function active?
● How does the drive respond to a discrepancy signal at a fail-safe digital input?
● How does the drive respond to limit value violations or if internal monitoring functions
respond?
● How do you acknowledge safety function faults?
● How do the safety functions mutually influence one another?
● What do the alarm and fault messages of the safety functions mean?
● How do you maintain the operational safety of the plant or machine?
● How do you replace defective components in the inverter or the inverter itself?
● How do you ensure that after a replacement the safety functions still function?
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD