Contents Your pH Perfect has been designed to maintain your pools pH at an ideal balance. Your pools pH balance is the most important component for water chemistry for your skin, eyes hair etc plus it also to keeps your sanitiser working at its most efficient. (consider using a Zodiac Chlor Perfect to...
1. Contents of this Package symbol indicates important information that must imperatively be taken into account in order to avoid risk of injury to persons or damage to the appliance. symbol indicates useful information. 1.1 Identification of parts Control box 2.
1.2 The Control Panel Blue Backlighted LCD 1 line 16 white character screen. Left side warning zone (alarms) / Right side pH display Peristaltic pump Connection for injection tube. ...
Before carrying out any installation or maintenance of the pH Perfect control centre, disconnect it from the mains power supplies. Before starting to install the pH Perfect, check that you have all the components listed above and ensure you read this instruction manual carefully.
2.3 Installation Diagram Installation of the pH Perfect on the filtration system: It is recommended that pH Perfect be installed after the filter (and any heating device) but before the salt chlorinator cell... if no salt chlorinator is installed it...
2.4 Installation of the Sensor POD Use a straight section of horizontal pipe located past all other equipment including pump, filter, heater etc (30 cm long is best). 2. POD should be installed so that once the sensor is fitted it is in an upright position 3.
Page 8
8. Once all connections are made place the suction line into the container and screw the anti fume cap down into position. (see picture D) Please note: When installing pH Perfect ensure your acid is diluted to a 50/50 mix of acid/water before screwing the cap down...
3. Starting up and operating 3.1 Calibration procedure The sensor must be calibrated when your pH Perfect is first installed and ideally every two months there after to obtain the best operating conditions. Calibration must be done each time your pool is restarted at the beginning of the season.
If your water chemistry is badly out of balance please bring your pool pH within balance before activating the pH Perfect. The pH Perfect peristaltic pump is self-starting. However, it is possible to operate it manually by keeping the ”p“ Navigation button pressed.
(> 150 ppm). In order to always have an optimal balance, the pH Perfect has a function making it possible to adjust the quantities of potentially injected corrector product depending on the total water hardness (see...
Accept the choice by pressing the “CAL/Enter” button. 4.3 Set point The default set point on the pH Perfect is 7.4 pH (D)To change it when in the “Settings” menu, enable the option list by pressing the “CAL/Enter” button (the pH value fl ashes). Then select the value chosen using the “p”...
#2: “Stop OFA” is displayed on the LCD screen after reaching 100% of the OFA programmed time (4 hours in the original setting). The appliance is then safe. To cancel this protection and start your pH Perfect, press the “CAL/Enter” button (possible on the 2 steps of the OFA alarm).
Accept the choice by pressing the “CAL/Enter” button. Special functions of the OFA To prevent “false” alarms just after installing a pH Perfect (if the pH is poorly balanced and the chlorine needed therefore high), the OFA may be temporarily disabled for 24 or 48 hours: •...
5.2 Winterizing the pH Perfect When pH Perfect has to be winterised, it is advisable to pump clean water through it in order to rinse the peristaltic pipe using the self-priming function and pressing the navigation button “p”...
6. Water quality Even though pH Perfect is an automated delivery device it is still a requirement to have the pool water regularly checked for balance and chemistry. See the table below for recommendations of frequency Zodiac Group Australia cannot be held liable if these rules are not followed.
8. Problem solving Problem Cause Remedy Make sure that the sensor-pH Perfect connection is not short-circuited (between Displayed pH the central core of the cable and the exterior Problem with cable and/ level doesn't sheathing) or connector seem to change ...
(a) if the Product has not been installed in accordance with Zodiac's installation instructions; (b) if the Product has been modified other than as authorised by Zodiac Australia or if a component part has been replaced by a part that is not a genuine Zodiac product;...
Product should be returned to the Authorised Dealer at the address where the Purchaser purchased the Product or whether warranty service will be provided in the field, repaired at a Zodiac workshop or at the premises of an authorized Zodiac warranty agent.
Page 20
Zodiac is a registered trademark of Zodiac Group Australia Pty Ltd ABN 87 002 641 965 ZODIAC CUSTOMER SERVICE CENTRE Zodiac Group Australia: 219 Woodpark Rd, Smithfield, NSW 2164 Australia Tel: 1300 763 021 Fax: 1300 781 688 Email: apac.aftersales@zodiac.com www.zodiac.com.au...