Installing
4.6 Connecting the inverter to the fieldbus
You have the following options to specify the IP address of the inverter:
● You specify the IP address via an engineering software, e.g. via HW-Config or STARTER.
● The IO Controller assigns an IP address to the inverter.
Telegram
Set the same telegram in the inverter as in the IO Controller. Interconnect the telegrams in the
control program of the IO Controller with the signals of your choosing.
Application examples
You can find application examples for PROFINET communication on the Internet:
Controlling the speed of a SINAMICS G120/S120 with S7-300/400 via PROFINET
support.industry.siemens.com/cs/ww/en/view/38844967)
Controlling the speed of a SINAMICS G110M/G120/G120C/G120D with S7-300/400F via
PROFINET, with Safety Integrated (via terminal) and HMI
support.industry.siemens.com/cs/ww/en/view/60441457)
Controlling the speed of a SINAMICS G110M/G120 (Startdrive) with S7-1500 (TO) via
PROFINET, with Safety Integrated (via terminal) and HMI
support.industry.siemens.com/cs/ww/en/view/78788716)
4.6.1.4

Installing GSDML

Procedure
To install the GSDML of the inverter in the engineering system of the controller, proceed as
follows:
1. Save the GSDML to your PC .
– From the Internet: GSDML
– From your inverter:
2. Unzip the GSDML file on your computer.
3. Import the GSDML into the engineering system of the controller.
You have now installed the GSDML in the engineering system of the controller.
124
Drive control via PROFIBUS or PROFINET (Page 196)
26641490)
Insert a memory card into the inverter.
Set p0804 = 12.
The inverter writes the GSDML as zipped file (*.zip) into directory /SIEMENS/SINAMICS/
DATA/CFG on the memory card.
(https://support.industry.siemens.com/cs/ww/en/view/
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2017, FW V4.7 SP6, A5E34259001B AD
(https://
(https://
(https://