Network Read, Network Write - Siemens SIMATIC S7-200 System Manual

Hide thumbs Also See for SIMATIC S7-200:
Table of Contents

Advertisement

SIMATIC Instructions

Network Read, Network Write

L
NETR
A
EN
D
F
TBL
B
D
PORT
NETW
EN
TBL
PORT
S
NETR
T
L
NETW
221
222
Inputs/Outputs
TBL
VB, MB, *VD, *AC, *LD
PORT
Constant
9-180
The Network Read instruction initiates a communication
operation to gather data from a remote device through
ENO
the specified port (PORT), as defined by the table (TBL).
The Network Write instruction initiates a communication
operation to write data to a remote device through the
specified port (PORT), as defined by the table (TBL).
The NETR instruction can read up to 16 bytes of
ENO
information from a remote station, and the NETW
instruction can write up to 16 bytes of information to a
remote station. You may have any number of
NETR/NETW instructions in the program, but only a
maximum of eight NETR and NETW instructions may be
activated at any one time. For example, you can have
TBL,PORT
four NETRs and four NETWs, or two NETRs and six
TBL,PORT
NETWs active at the same time in a given S7-200.
Figure 9-67 defines the table that is referenced by the
TBL parameter in the NETR and NETW instructions.
224
226
NETR: Error conditions that set ENO = 0:
SM4.3 (run-time), 0006 (indirect address)
NETW: Error conditions that set ENO = 0:
SM4.3 (run-time), 0006 (indirect address)
Operands
S7-200 Programmable Controller System Manual
Data Types
BYTE
BYTE
A5E00066097-02