hit counter script

Connecting A Motor Holding Brake - Siemens SINAMICS G120 Operating Instructions Manual

Low voltage converter with the cu240b-2 and cu240e-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Installing
4.5 Connecting the line supply, motor, and inverter components
4.5.4

Connecting a motor holding brake

The inverter uses the Brake Relay to control the motor holding brake. Two types of Brake
Relay exist:
● The Brake Relay controls the motor holding brake
● The Safe Brake Relay controls a 24 V motor holding brake and monitors the brake control
for short-circuit or cable breakage.
Note
Brake Relay and Safe Brake Relay
The Brake Relay and the Safe Brake Relay do not differ from each other in the installation
and the connection to the inverter.
Connection to the inverter
To ensure that you have the correct cable for connecting the Brake Relay irrespective of the
inverter size, you are supplied with two preassembled cables with different lengths. Connect
the appropriate cable to the Brake Module and to the inverter as shown below.
If you are using your own cable, ensure that the cable is insulated and rated for 600 V.
86
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC