hit counter script

Ultratec G3000 Operator's Manual

Lsg mark ii
Hide thumbs Also See for G3000:

Advertisement

G3000 w/ LSG
Operator's Manual
www.ultratecfx.com
VER. 30.10.10

Advertisement

Table of Contents
loading

Summary of Contents for Ultratec G3000

  • Page 1 G3000 w/ LSG Operator’s Manual www.ultratecfx.com VER. 30.10.10...
  • Page 2: Table Of Contents

    Maintenance ................16 Exterior ................... 16 Heat Exchanger ..............16 Recommended Fluid ..............16 Troubleshooting Residual Buildup and Wet Output ..... 16 Warranty ................... 18 Contact Information ..............18 Note: Please read entire manual before operating the G3000 w/ LSG www.ultratecfx.com...
  • Page 3: Introduction

    The “LSG Mark II” couples with the G3000, offering the most advanced controls and fog output available. The LSG Mark II consumes approximately 8 lbs. of Liquid Carbon Dioxide per minute of operation at 350 PSI.
  • Page 4: Technical Specifications

    Weight: Installation version w/ cart: 100lbs less G3000 Roadcase version: 150lbs less G3000 Power Rating: 120 Volt A.C. 50/60 Hz. 20 Amps. (w/ G3000) 240 Volt A.C. 50/60 Hz. 10 Amps. (w/ G3000) Technical Drawings LSG Mark II w/ Cart...
  • Page 5: Lsg Stand Alone

    LSG Stand Alone LSG w/ Road Case www.ultratecfx.com...
  • Page 6: Operating Procedure

    G3000 output nozzle is centered in the LSG Mark II input. 2. Connect the blue twist lock connector from the LSG Mark II into Custom port on the rear panel of the G3000. 3. Power up the fog machine by turning on the power switch.
  • Page 7 8. Open valve(s) fully, by turning counter-clockwise. 9. When the G3000 is up to operating temperature, turn on the fog on the remote control. The CO2 will be activated first. After the appropriate delay time passes, fog issue will start. You will know when the gas has been purged from the supply hose by the difference in noise that the LSG Mark II makes.
  • Page 8: Lsg Mark Ii Low Pressure Using 350Lb. Liquid C02 Tank

    LSG Mark II Low Pressure using 350lb. liquid C02 tank These instructions are given for systems using a G3000 with LSG Control Option. Alternate control options are given further in this manual. 1. Place the G3000 output directly against the foam ring input of the LSG Mark II.
  • Page 9: Lsg Mark Ii High Power (Low Pressure)

    10. Open Liquid valve(s) fully, by turning counter-clockwise 11. When the G3000 is up to operating temperature, turn on the fog button on the remote control. The CO2 will be activated first. After the appropriate delay time passes smoke issue will start. You will know when the gas has been purged from the supply hose by the difference in noise that the LSG Mark II makes.
  • Page 10: Lsg Mark Ii High Power Combo

    Channel x + 2 1000% Flow, NOT used with High Pressure Liquid CO2 Note: When using the LSG High Power, the G3000 delay is controlled either manually via remote or via DMX. When fog and/or CO2 are activated, the LSG fan speed should be at least 25% to prevent back flow.
  • Page 11: Round Floor Pocket

    The pressure builder is a very important component in achieving the proper LSG Mark II operating pressure. We can monitor this operating pressure by observing the pressure gauge located on the top of the Liquid CO2 Tank. Ideally the operating pressure of the Liquid CO2 Tank is 310 - 330 p.s.i.g.
  • Page 12: Ducting

    The ducting is available insulated or non-insulated and can be purchased though an industrial supply company or from Ultratec Special Effects (Part # CLF ). The LSG Mark II may also be ducted vertically up to 20 feet to produce a waterfall or cascade effect. When ducting fog vertically, the remaining fog in the duct must not be allowed to backflow into the LSG Mark II.
  • Page 13: Lsg Mark Ii Ducting Suggestions

    78.5” square inches. For this example, we will try a 6” diameter duct: 0.78539 x 36=28 If we multiply the cross sectional area of the 6” duct by 3 duct outlets : 28 x 3= 84”. 84 is greater than 78.5 so the 6”...
  • Page 14: Fog Curtain / Waterfall

    Top View Fog Curtain / Waterfall www.ultratecfx.com...
  • Page 15: 10" Automatic Round Damper

    10” Automatic Round Damper The 10” Automatic Round Damper (ARD) is an inline damper that will open or close to allow or prevent fog from flowing down a run of 10” ducting. When using with a ‘Y’ connector as illustrated, fog may be diverted down either or both branches of ducting.
  • Page 16: Maintenance

    Maintenance Exterior The casing of the G3000 is stainless steel with a powder paint coating. To clean simply wash with mild soap and warm water. Heat Exchanger Using high quality Ultratec Special Effects fluid should result in a long heat exchanger life. (See warranty policy later in this manual).
  • Page 17 Less then a 25 Flow Rate setting on the fog machine remote. 9. Wrong Fluid is being used. Ultratec Special Effects Molecular should be the only fluid used. Longer lasting fogs can cause this but again it is not observed often. If another manufacturers fluid is used this will definitely cause this type of problem.
  • Page 18: Warranty

    Warning: Ultratec Special Effects Inc. considers all of it’s product to be safe for use in the application it was intended. Ultratec Special Effects takes no responsibility for misuse or incorrect use. Always refer to the Product Manual for proper use.

Table of Contents