Installation

3.1
Fitting the IOP

Fitting the IOP to the Control Unit

IOP power supply
The IOP has no internal power supply and derives its power directly from the Control Unit of
the Inverter through the RS232 interface. The IOP can also be connected to a PC and
derives its power through the USB connection.
To fit the IOP to the Inverter Control Unit the following procedure should be performed:
1. Place the bottom edge of the IOP casing into the lower recess of the Control Unit
2. Push the IOP forward until the top fastening clicks into place on the Control Unit housing.
Figure 3-1
Fitting the IOP to the Control Unit
Intelligent Operator Panel (IOP)
Operating Instructions, 03/2013, FW V1.4, A5E00110011A4 AB