Sign In
Upload
Manuals
Brands
Siemens Manuals
Transmitter
sitrans lr 460
Siemens sitrans lr 460 Manuals
Manuals and User Guides for Siemens sitrans lr 460. We have
7
Siemens sitrans lr 460 manuals available for free PDF download: Quick Start Manual, Operating Instructions Manual, Instruction Manual
Siemens sitrans lr 460 Operating Instructions Manual (187 pages)
Radar transmitters
Brand:
Siemens
| Category:
Transmitter
| Size: 5.66 MB
Table of Contents
Table of Contents
3
Introduction
9
Purpose of this Documentation
9
FW Revision History
10
Designated Use
10
Security Information
11
Transportation and Storage
11
Notes on Warranty
12
Safety Notes
13
Precondition for Use
13
Laws and Directives
13
Conformity with European Directives
14
Conformity with UK Regulations
14
Radio Equipment - EU Directive (RED) 2014/53/EU and UK Regulation si 2017/1206
15
Installations Only: Federal Communications Commission (FCC) Rules
15
Canadian Installations Only: Industry Canada (IC) Rules
15
Safety Notes
16
Safety Marking Symbols
17
Description
18
Sitrans Lr460
18
Installing/Mounting
19
Installation Location Requirements
19
Mounting Location
20
Nozzle Design
21
Nozzle Location
22
Installation in Vessel with Obstructions
23
Easy Aimer Installation
24
Air Purging System (Optional)
26
Universal Slotted Flange (for Use with Air Purging Option Only)
28
Optional Dust Cap
29
Incorrect Disassembly
31
Connecting
32
Basic Safety Notes
32
Connecting SITRANS LR460
33
HART Wiring
34
Connecting HART
35
PROFIBUS Wiring
37
Connecting PROFIBUS PA
38
Product Nameplate
39
Instructions Specific to Hazardous Area Installations
40
European Directive 2014/34/EU, Annex II, 1.0.6 and UK Regulation si 2016/1107
40
Special Conditions for Safe Use
41
Commissioning
42
Basic Safety Notes
42
Quick Start
43
Activating SITRANS LR460
43
RUN Mode Display
44
Programming SITRANS LR460
44
The Handheld Programmer and PROGRAM Mode Display
45
Quick Start Wizard Via the Handheld Programmer
46
Quick Start (1.)
47
Quick Start Wizard Via SIMATIC PDM
49
Quick Start Wizard Steps
51
Level Application Example
54
Auto False Echo Suppression
55
Remote Operation
56
Operating SITRANS LR460 Via SIMATIC PDM
56
Echo Profile Saving and Viewing
57
Trend Diagram (Level Trend over Time)
58
Manual TVT Shaper
59
Accessing Functions in PDM
60
Changing Parameter Settings Via SIMATIC PDM
61
Parameters Accessed Via Pull-Down Menus
62
Pull-Down Menus for HART Via SIMATIC PDM
63
Pull-Down Menus for PROFIBUS PA Via SIMATIC PDM
64
Simulation
65
Parameter Assignment
67
Parameter Menus
67
Quick Start Wizard
67
Quick Start (1.)
68
Identification (IDENT) (2.)
71
Operation Unit
71
Configuration (CONFIG) (for HART Devices) (2.1.)
71
Configuration (CONFIG) (for PROFIBUS PA Devices) (2.1.)
73
Device (2.2.)
75
Statistics (STATS) (2.3.)
77
Input (3.)
77
Standard Setup (ST SETUP) (3.2.)
78
Sensor Calibration (SENSOR CAL) (3.3.)
79
Measuring Limits (MEAS LIM) (3.4.)
82
Detailed Setup (DT SETUP) (3.5.)
83
Fail-Safe (3.5.1.)
83
Echo Select (ECHO SEL) (3.5.2.)
84
Sampling (ECHO SAMP) (3.5.3.)
86
Range (3.5.4.)
87
TVT (Auto False Echo Suppression) Setup (3.5.6.)
88
TVT Shaper (3.5.7.)
92
Rate (3.5.8.)
93
Echo Information (ECHO INFO) (3.6.)
94
Level Transducer Block (TB VALUES) (3.6.1.)
94
Echo Quality (ECHO QUAL) (3.6.2.)
94
Output (4.)
95
Analog Input Function Block 1 (AIFB 1)
95
Target Mode (TARGET MDE) (4.1.1.)
95
Unit (4.1.2.)
96
Filter Time Constant (FILT TIME) (4.1.3.)
96
Function (CHANNEL) (4.1.4.)
96
Batch Information (BATCH) (PROFIBUS PA Only)
96
Process Value Scale (PR VAL SCL) (4.1.6.)
97
Output Scale (out SCALE) (4.1.7.)
98
Output Limits (OUT. LIM) (4.1.8.)
99
Failsafe (PROFIBUS PA Only) (4.1.9.)
101
Human Interface (INTERFACE) (4.1.A)
101
Analog Input Function Block 2 (AIFB 2) (4.2.)
101
Ma Output (HART Only) (4.3.)
101
Relay Configuration (RLY CONFIG) (HART Only) (4.4.)
104
Maintenance Settings (MAINT SET) (6.)
104
Remaining Device Lifetime (DVC REMLIF) (6.1.)
104
Remaining Sensor Lifetime (SNS REMLIF) (6.2.)
109
Service Interval (SERVICE) (6.3.)
112
Condensed Status Setup (COND SETUP) PROFIBUS PA Only (7.)
114
Service and Maintenance
118
Maintenance
118
Unit Repair and Excluded Liability
118
Cleaning
119
Cleaning the Antenna
119
Return Procedure
120
Disposal
120
Troubleshooting
121
General Fault Codes
123
Technical Specifications
125
Power
125
Performance
125
Interface
126
Mechanical
127
Programmer (Infrared Keypad)
127
Environmental
128
Process
128
Communication
129
Approvals
129
Dimension Drawing
130
Dimension Drawings
130
Technical Reference
131
Principles of Operation
131
Measurement Response
131
Echo Processing
132
Profile Monitoring Via SIMATIC PDM
132
False Echoes
133
Auto False Echo Suppression
134
Near Range (Blanking)
134
Echo Confidence
134
Fail-Safe Mode
135
Maximum Process Temperature Chart
136
HART Communications
138
HART Communication
138
HART Information Structure
140
Block Model
140
HART Communicator 375 Menu Structure
141
Level Transducer Block (LTB)
144
Communications Via PROFIBUS PA
146
Communication Via PROFIBUS PA
146
Operating as a Profile Device
147
Cyclic Versus Acyclic Data
148
Cyclic Data
148
Status Byte
149
Condensed Status
151
Diagnosis Reply (Available Cyclically)
153
Acyclic Diagnostics
153
Extended Mode Diagnosis
154
Condensed Mode Diagnosis
155
Acyclic Extended Diagnostics (General Fault Codes)
156
Acyclic Data
159
PROFIBUS PA Profile Structure
160
PROFIBUS Level Device Design
160
Block Model
160
Transducer Block Function Groups
161
How the Transducer Block Works
162
Analog Input Function Blocks 1 and 2
164
AIFB Function Groups
164
How Aifbs Work
164
AIFB Execution Steps
165
Local Operation Interface
166
The LCD Display
166
RUN Mode (Startup Display)
166
The Handheld Programmer
167
Handheld Programmer: Key Functions in RUN Mode
168
Programming Via the Handheld Programmer
169
Handheld Programmer: Key Functions in Navigation Mode
170
Handheld Programmer: Key Functions in Edit Mode
170
LCD Menu Structure
172
List of Abbreviations
177
Abbreviations
177
Product Documentation and Support
179
Product Documentation
179
Technical Support
180
Glossary
181
Index
186
Advertisement
Siemens sitrans lr 460 Quick Start Manual (197 pages)
Radar Transmitter
Brand:
Siemens
| Category:
Transmitter
| Size: 2.91 MB
Table of Contents
Technical Support
3
Safety Guidelines
4
Canadian Installations Only: Industry Canada (IC) Rules
4
Specifications
5
The Manual
5
Installation
6
Connecting HART
9
Power Demands
10
Bus Termination
10
Connecting PROFIBUS PA
11
Programming SITRANS LR460
12
Activating SITRANS LR460
12
Quick Start Wizard Via the Handheld Programmer
12
Quick Start
13
Using the Handheld Programmer
13
Quick Start Wizard Via SIMATIC PDM
15
Device Description (DD)
15
Configuring a New Device
15
Step 2 - Application Type
16
Step 3 - Range Setup
16
Hazardous Area Installations
17
Instructions Specific to Hazardous Area Installations (Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
17
SITRANS LR460 Kvikstart Manual
35
Teknisk Support
35
Kun for Installationer I USA: Regler Fra Federal Communications Commission (FCC)
36
Tekniske Data
37
Installation
38
Mundstykkets Udformning
39
Mundstykkets Placering
39
Elektrisk Installation
40
Tilslutning Af HART
41
Tilslutning Af PROFIBUS PA
43
Kvikstartguide Via den Håndholdte Programmeringsenhed
44
Device Description
47
Kvikstartguide Via SIMATIC PDM
48
SITRANS LR460 Kurzanleitung
51
Technischer Support
51
Sicherheitstechnische Hinweise
52
Technische Daten
53
Installation
54
Design des Montagestutzens
55
Anbringung des Montagestutzens
55
Anschluss HART
57
Anschluss PROFIBUS PA
59
Schnellstartassistent mit dem Handprogrammiergerät
60
Konfiguration eines Neuen Gerätes
63
Schnellstartassistent über SIMATIC PDM
64
SITRANS LR460 - Puesta en Marcha Rápida
83
Soporte Técnico
83
Indicaciones de Seguridad
84
Acerca del Manual
85
Datos Técnicos
85
Suministro de Corriente
85
Instalación
86
Montaje de la Boquilla
87
Conexión HART
89
Alimentación Eléctrica
90
Conexión PROFIBUS PA
91
Arranque Rápido
93
Device Description (DD)
95
Configuración de un Nuevo Aparato
95
SITRANS LR460 Mise en Service Rapide
99
Assistance Technique
99
Consignes de Sécurité
100
Le Manuel D'utilisation
101
Caractéristiques Techniques
101
Alimentation Électrique
101
Installation
102
Montage
102
Remarques Importantes
103
Positionnement du Piquage
103
Connexion HART
105
Configuration Api/Ma Avec HART (Nominale)
105
Mise en Service Rapide
109
Device Description (DD)
111
Supporto Tecnico
115
Indicazioni DI Sicurezza
116
Caratteristiche Tecniche
117
Installazione
118
Collegamento Elettrico
120
Collegamenti HART
121
Requisiti DI Alimentazione
122
Collegamenti PROFIBUS PA
123
Avvio Rapido
125
Device Description (DD)
127
Impostazione DI un Apparecchio
127
SITRANS LR460 Quick Start Handleiding
131
Technische Ondersteuning
131
Alleen Voor US Installaties: Federal Communications Commission (FCC) Regelgeving
132
Locatie Van de Sok
135
Quick Start Wizard Via de Handprogrammeereenheid
140
Device Description (DD)
143
Configureren Van Een Nieuw Apparaat
143
SITRANS LR460 Manual de Partida Rápida
147
Suporte Técnico
147
Diretrizes de Segurança
148
Design Do Bocal
151
Localização Do Bocal
151
Instalação Elétrica
152
Conexão Do HART
153
Conexão Do PROFIBUS PA
155
Assistente de Partida Rápida por Meio Do Programador Portátil
156
Partida Rápida
157
Configuração de um Novo Dispositivo
159
Assistente de Partida Rápida por Meio de SIMATIC PDM
160
SITRANS LR460 - Pikakäyttöopas
163
Tekninen Tuki
163
Tekniset Tiedot
165
Säteilyaukon Suunnittelu
167
Säteilyaukon Sijoitus
167
PROFIBUS Pa:n Kytkeminen
171
RUN-Käyttötilan Näyttö
172
Ohjattu Pikakäyttötoiminto Käsiohjelmointilaitteen Avulla
172
Uuden Laitteen Kokoonpanoasetukset
175
Ohjattu Pikakäyttötoiminto SIMATIC Pdm:n Avulla
176
Räjähdysvaarallisten Tilojen Asennusta Koskevat Ohjeet (ATEX-Direktiivi 94/9/EY, Liite II, Kohta 1/0/6)
177
SITRANS LR460 Snabbstartsmanual
179
Riktlinjer För Säkerhet
180
Anslutning Av HART
185
Typisk Plc/Ma-Konfiguration Med HART
185
Anslutning Av PROFIBUS PA
187
Konfigurering Av en Ny Apparat
191
Snabbstartsvägledning Via SIMATIC PDM
192
For more Information
196
Siemens sitrans lr 460 Instruction Manual (123 pages)
Brand:
Siemens
| Category:
Transmitter
| Size: 1.92 MB
Table of Contents
Table of Contents
3
Safety Notes
9
Safety Marking Symbols
9
FCC and IC Conformity
10
The Manual
11
Application Examples
11
Support
11
Abbreviations and Identifications
11
Sitrans Lr 460
13
Programming
13
Approvals and Certificates
13
System Implementation
13
Specifications
14
Sitrans Lr 460
14
Power
14
Performance
14
Interface
15
Programmer (Infrared Keypad)
16
Mechanical
16
Environmental
17
Process
17
Communication
17
Approvals
18
Dimensions
19
Standard Configuration
19
Installation
20
Mounting Location
20
Key Considerations
21
Nozzle Design
21
Nozzle Location
21
Device Orientation
21
Installation in Vessel with Obstructions
22
Easy Aimer Installation
23
Air Purging System
24
Universal Slotted Flange (for Use with Air Purging Option Only)
25
Optional Dust Cap
26
Wiring
27
Connecting SITRANS LR 460
27
HART Wiring
28
Connecting HART
28
PROFIBUS Wiring
29
Connecting PROFIBUS PA
30
Hazardous Area Installations
31
Product Nameplate
31
Instructions Specific to Hazardous Area Installations
31
Quick Start
34
Activating SITRANS LR 460
34
RUN Mode Display
34
Programming SITRANS LR 460
35
The Handheld Programmer and PROGRAM Mode Display
35
Quick Start Wizard Via the Handheld Programmer
36
Quick Start Wizard Via SIMATIC PDM
38
Device Description (DD)
38
Quick Start Wizard Steps
39
Level Application Example
42
Auto False Echo Suppression
43
Operating SITRANS LR 460 Via SIMATIC PDM
44
Functions in SIMATIC PDM
44
SIMATIC PDM Rev. 6.0, SP2 Features
44
Echo Profile Saving and Viewing
45
Trend Diagram (Level Trend over Time)
45
Manual TVT Shaper
46
Accessing Functions in PDM
47
Changing Parameter Settings Via SIMATIC PDM
48
Configuring a New Device
48
Calibrating LR 460 Via PDM
49
Parameters Accessed Via Pull-Down Menus
49
Reset
49
Configuration Flag Reset (HART Only)
49
Auto False Echo Suppression
49
D/A (Digital/Analog) Trim
50
Simulate AO (Analog Output)
50
Simulation
50
Parameter Reference
51
Parameter Menus
51
Pull-Down Menus Via SIMATIC PDM
51
Quick Start Wizard
52
Quick Start
52
Language
52
Application Type
52
Operation
52
Units
53
High Calibration Point
53
Low Calibration Point
53
Rate
53
Apply Changes
53
Identification
53
Operation Unit
53
Configuration
54
Device
55
Statistics
56
Input
57
Static Revision Number
57
Class
57
Standard Setup
57
Sensor Calibration
58
Measuring Limits
60
Detailed Setup
60
Echo Information
68
Output
68
Aifb1
68
Aifb2
72
Ma Output
72
Relay Configuration
74
Device Certification
74
Remaining Device Lifetime
75
Remaining Sensor Lifetime
75
Service Interval
76
Calibration Interval
76
Appendix A: Technical Reference
77
Principles of Operation
77
Measurement Response
77
Echo Processing
78
Profile Monitoring Via SIMATIC PDM
78
Time Varying Threshold (TVT)
78
Echo Selection
78
False Echoes
79
Auto False-Echo Suppression
79
Near Range (Blanking)
80
Echo Confidence
80
Loss of Echo (LOE)
80
LOE Timer
80
Fail-Safe Mode
80
Maximum Process Temperature Chart
82
Appendix B: Troubleshooting
83
General Fault Codes/Profibus PA Extended Diagnostics
86
Appendix C: Maintenance
90
Unit Repair and Excluded Liability
90
Appendix D: Local Operation Interface
91
The LCD Display
91
RUN Mode (Startup Display)
91
PROGRAM Mode Display
91
The Handheld Programmer
92
Hand-Held Programmer: Key Functions in RUN Mode
92
PROGRAMMING Via the Handheld Programmer
92
Hand-Held Programmer: Key Functions in Navigation Mode
93
Hand-Held Programmer: Key Functions in Edit Mode
93
Individual Parameter Reset
93
Appendix E: HART Communications
94
HART Device Description (DD)
94
SIMATIC Process Device Manager (PDM)
94
HART Modem Interface for SIMATIC PDM
94
HART Version
95
Burst Mode
95
HART Communication Parameter
95
Appendix F: HART Information Structure
96
Block Model for Recording and Processing Measured Values
96
Description of the Blocks
97
Appendix G: Remote Operation Via PROFIBUS PA
98
Configuration Tool
98
Simatic Pdm
98
Device Description
98
Configuration
99
The GSD File
99
Setting the PROFIBUS Address
99
Configuring a New Device: Procedure
99
Configuring PROFIBUS PA with an S7-300/ 400 PLC
100
Calibration Via SIMATIC PDM
100
Appendix H: Communication Via PROFIBUS PA
101
Cyclic Versus Acyclic Data
101
Cyclic Data
101
Status Byte
102
Diagnostics
103
Diagnosis Reply (Applies Only to Cyclic Masters)
103
Acyclic Diagnostics
103
Acyclic Extended Diagnostics (General Fault Codes)
104
Acyclic Data Transmission
104
Appendix J: PROFIBUS PA Profile Structure
105
PROFIBUS Level Device Design
105
Block Model for Recording and Processing Measured Values
105
Description of the Blocks
106
Level Transducer Block Function Groups
106
Analog Input Function Blocks 1 and 2
108
Appendix K: Software Revision History
111
Glossary
113
Index
117
LCD Menu Structure
119
Advertisement
Siemens sitrans lr 460 Instruction Manual (107 pages)
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 1.06 MB
Table of Contents
Table of Contents
3
Table of Contents
7
Safety Notes
7
Safety Marking Symbols
7
The Manual
8
Application Examples
9
Abbreviations and Identifications
9
Programming
10
Approvals and Certificates
10
Sitrans Lr 460
12
System Implementation
13
Typical Plc/Ma Configuration with HART
13
Typical Plc/Ma Configuration with PROFIBUS PA
13
Specifications
15
Sitrans Lr 460
15
Power
15
Performance
15
Interface
16
Programmer (Infrared Keypad)
16
Mechanical
17
Environmental
18
Process
18
Communication
18
Approvals
19
(Verify against Device Nameplate)
19
SITRANS LR 460 Dimensions
20
Flange Dimensions
21
Installation
23
Mounting Location
23
Beam Width
25
Installation in Mounting Nozzle
25
Easy Aimer Installation
26
Easy Aimer Positioning
26
Wiring
29
Connecting SITRANS LR 460
29
AC Version
30
DC Version
30
Hazardous Area Installations
32
Product Nameplate
32
Instructions Specific to Hazardous Area Installations
32
EU Equivalency
33
Ma Start up
36
Startup Display (RUN Mode)
36
Programming SITRANS LR 460
37
The Handheld Programmer
37
PROGRAM Mode Display
38
Security
38
Local Operation Enable
38
Remote Operation Enable
38
Write Locking
39
How to Do a Master Reset
39
Fault Reset
39
Quick Setup
39
Performing Calibration Via PDM
39
Using Auto False Echo Suppression
40
Level Application Example
41
Local Operation
43
Programming Via the Handheld Programmer
43
Parameter Menu Structure
43
The LCD Display
43
Using the Handheld Programmer
44
Security
44
Local Operation Enable
44
Write Locking
44
Remote Operation Enable
44
How to Do a Master Reset
45
Master Reset
45
Individual Parameter Reset
45
Fault Reset
45
Device Calibration
46
LCD Menu Structure
47
HART Communications
51
HART Device Description (DD)
51
SIMATIC Process Device Manager (PDM)
51
Maintenance Settings (Accessible Via PDM Only)
51
Supported HART Commands
52
Universal and Common Practice Commands
53
Device Specific Commands
53
Remote Operation Via PROFIBUS PA
56
Simatic Pdm
56
Device Description
56
Configuration
57
The GSD File
57
Setting the PROFIBUS Address
57
Bus Termination
57
Power Demands
57
Cyclic Versus Acyclic Data
57
Cyclic Data
58
Status Byte
58
Diagnostics
59
Diagnosis Reply (Applies Only to Cyclic Masters)
59
Acyclic Diagnostics
60
Acyclic Extended Diagnostics (General Fault Codes)
61
Acyclic Data
61
Configuration Example
61
PROFIBUS PA Profile Structure
62
PROFIBUS Level Device Design
62
Block Model for Recording and Processing Measured Values
62
Description of the Blocks
63
Transducer Block Function Groups
63
Analog Input Function Blocks 1 and 2
65
Appendix A: Parameter Descriptions
69
Identification
69
Operation Unit
69
Configuration
69
Device
70
Statistics
72
Input
72
Static Revision Number
72
Class
72
Reset Filter
72
Standard Setup
72
Sensor Calibration
74
Measuring Limits
75
Detailed Setup
76
Output
83
Aifb1
83
Aifb2
85
Device Certification
86
Maintenance Settings
86
Remaining Device Lifetime
86
Remaining Sensor Lifetime
86
Service Interval
86
Calibration Interval
87
Condensed Status Setup
87
Condensed Status Mode
87
Appendix B: Technical Reference
89
Principles of Operation
89
Measurement Response
89
Echo Lock
90
Loss of Echo (LOE)
90
LOE Timer
91
Failsafe Mode
91
False Echoes
91
Near Range (Blanking)
91
Auto False-Echo Suppression
91
Maximum Process Temperature Chart
93
Appendix C: Troubleshooting
94
General Fault Codes
95
Appendix D: Maintenance
99
Unit Repair and Excluded Liability
99
Appendix E: Software Revision History
100
Glossary
101
Index
105
Siemens sitrans lr 460 Operating Instructions Manual (155 pages)
Radar Transmitters
Brand:
Siemens
| Category:
Transmitter
| Size: 1.86 MB
Table of Contents
Table of Contents
3
Safety Notes
7
Safety Marking Symbols
7
FCC and IC Conformity
8
The Manual
9
Technical Support
9
Sitrans Lr460
12
Specifications
13
Power
13
Performance
13
Interface
14
Programmer (Infrared Keypad)
15
Mechanical
15
Environmental
16
Process
16
Communication
16
Approvals
17
Dimensions
18
Standard Configuration
18
Installation
19
Mounting Location
19
Key Considerations
20
Nozzle Design
20
Nozzle Location
21
Device Orientation
21
Installation in Vessel with Obstructions
21
Easy Aimer Installation
22
Air Purging System (Optional)
23
Universal Slotted Flange (for Use with Air Purging Option Only)
24
Optional Dust Cap
25
Wiring
27
Connecting SITRANS LR460
27
HART Wiring
28
PROFIBUS Wiring
29
Hazardous Area Installations
31
Product Nameplate
31
Instructions Specific to Hazardous Area Installations
31
Quick Start
33
Activating SITRANS LR460
33
RUN Mode Display
33
Programming SITRANS LR460
34
The Handheld Programmer and PROGRAM Mode Display
34
Quick Start Wizard Via the Handheld Programmer
35
Quick Start Wizard Via SIMATIC PDM
37
Device Description (DD)
37
Quick Start Wizard Steps
38
Level Application Example
42
Auto False Echo Suppression
42
Operating SITRANS LR460 Via SIMATIC PDM
43
Functions in SIMATIC PDM
43
Features of SIMATIC PDM Rev. 6.0 SP3 (or Higher)
43
Features of SIMATIC PDM Rev. 5.2 SP1
43
Echo Profile Saving and Viewing
44
Trend Diagram (Level Trend over Time)
44
Manual TVT Shaper
45
Accessing Functions in PDM
46
Changing Parameter Settings Via SIMATIC PDM
47
Configuring a New Device
47
Calibrating LR460 Via PDM
47
Parameters Accessed Via Pull-Down Menus
47
Reset
47
Configuration Flag Reset (HART Only)
48
Auto False Echo Suppression
48
D/A (Digital/Analog) Trim (HART Only)
48
Simulate AO (Analog Output) (HART Only)
48
Simulation
48
Parameter Reference
51
Parameter Menus
51
Pull-Down Menus for HART Via SIMATIC PDM
51
Pull-Down Menus for PROFIBUS PA Via SIMATIC PDM
52
Quick Start Wizard
53
Quick Start
53
Identification (IDENT)
55
Input
61
Output
74
Condensed Status Setup (COND SETUP) (PROFIBUS PA Only)
94
Appendix A: Technical Reference
97
Principles of Operation
97
Measurement Response
97
Echo Processing
98
Profile Monitoring Via SIMATIC PDM
98
Time Varying Threshold (TVT)
98
Echo Selection
98
False Echoes
99
Auto False-Echo Suppression
99
Near Range (Blanking)
100
Echo Confidence
100
Loss of Echo (LOE)
100
LOE Timer
100
Siemens sitrans lr 460 Operating Instructions Manual (45 pages)
Radar transmitters
Brand:
Siemens
| Category:
Transmitter
| Size: 1.67 MB
Table of Contents
Table of Contents
3
Introduction
5
Purpose of this Documentation
5
FW Revision History
6
Designated Use
6
Security Information
7
Transportation and Storage
7
Notes on Warranty
8
Safety Notes
9
Precondition for Use
9
Laws and Directives
9
Conformity with European Directives
10
Conformity with UK Regulations
10
Radio Equipment - EU Directive (RED) 2014/53/EU and UK Regulation si 2017/1206
11
Installations Only: Federal Communications Commission (FCC) Rules
11
Canadian Installations Only: Industry Canada (IC) Rules
12
Description
14
Sitrans Lr460
14
Installing/Mounting
15
Mounting Location
15
Nozzle Design
16
Nozzle Location
17
Installation in Vessel with Obstructions
18
Easy Aimer Installation
19
Air Purging System (Optional)
21
Universal Slotted Flange (for Use with Air Purging Option Only)
23
Optional Dust Cap
24
Incorrect Disassembly
26
Installation Location Requirements
27
Connection
28
Basic Safety Notes
28
Safety Notes
28
Connecting SITRANS LR460
29
HART Wiring
30
Connecting HART
31
PROFIBUS Wiring
32
Connecting PROFIBUS PA
34
Product Nameplate
35
Instructions Specific to Hazardous Area Installations
36
European Directive 2014/34/EU, Annex II, 1.0.6 and UK Regulation si 2016/1107
36
Special Conditions for Safe Use
37
Technical Specifications
38
Power
38
Performance
38
Interface
39
Mechanical
40
Programmer (Infrared Keypad)
40
Environmental
41
Process
42
Communication
42
Approvals
42
Product Documentation and Support
43
Product Documentation
43
Technical Support
44
Index
45
Siemens sitrans lr 460 Quick Start Manual (17 pages)
4-wire, 24 GHz FMCW radar level transmitter
Brand:
Siemens
| Category:
Transmitter
| Size: 0.62 MB
Table of Contents
Safety Guidelines
3
Canadian Installations Only: Industry Canada (IC) Rules
3
Installation
4
Connecting HART
7
Power Demands
8
Bus Termination
8
Connecting PROFIBUS PA
9
Programming SITRANS LR460
10
Activating SITRANS LR460
10
Quick Start Wizard Via the Handheld Programmer
10
Quick Start
11
Quick Start Wizard Via SIMATIC PDM
13
Device Description (DD)
13
Configuring a New Device
13
Step 2 - Application Type
14
Step 3 - Range Setup
14
Hazardous Area Installations
15
Instructions Specific to Hazardous Area Installations (Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
15
Advertisement
Related Products
Siemens SITRANS LR25
Siemens SITRANS LR560
Siemens SITRANS LR100
Siemens SITRANS LR150
Siemens SITRANS LR200 7ML5423
Siemens SITRANS LR500 Series
Siemens SITRANS LR550
Siemens SITRANS LR530
Siemens SITRANS LR580
Siemens SITRANS TW
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL