Chapter 4. Cabling the switch module and the SFP+ module

This chapter describes how to cable the switch module and its optional devices.
Note: The illustrations in this document might differ slightly from your hardware.

Connecting the serial console cable

To connect the serial console cable to the switch module, connect the serial cable
that came with the switch module to the RS-232 serial console connector of the
switch module and the other end of the cable to the console device.

Disconnecting the serial console cable

To disconnect the serial console cable, gently pull the cable from the switch module.

Connecting the SFP+ module cable

Attention:
v Do not route the cable along a folding cable-management arm.
v When you attach the cable to a device on slide rails, leave enough slack in the
v Route the cable away from places where it can be snagged by other devices in
v Do not overtighten the cable straps or bend the cables to a radius of less than 38
v Do not put excess weight on the cable at the connection point. Make sure that
© Copyright IBM Corp. 2012
To avoid damage to the fiber-optic cables, follow these guidelines:
cable so that it does not bend to a radius of less than 38 mm (1.5 in.) when the
device is extended or become pinched when the device is retracted.
the rack.
mm (1.5 in.).
the cable is well supported.