5.1
Custom Hand mode
Overview
The custom hand mode allows the user to setup a command source and setpoint source
directly from the Intelligent Operator Panel (IOP).
When the custom hand mode has been set, the IOP wheel can be used as the setpoint
source.
The Auto mode is unaffected by any changes made by the custom hand mode function.
A breakdown of all the interconnection inputs are given in the table below.
An example of setting up the custom hand mode is given in the instructions below.
Table 5- 1
Interconnection inputs for Status Word 1 in Custom Hand mode
Standard interconnection
r8540
STW 1 from IOP
Bit0
ON/OFF key
Bit1
Two quick press of the OFF key
Bit2
A long press of the OFF key
Bit3
Reserved
Bit4
Reserved
Bit5
Reserved
Bit6
Reserved
Bit7
Alarms menu acknowledge all
faults
Bit8
Jog 1 (Control menu)
Bit9
Jog 2 (Control menu)
Bit10
Reserved
Bit11
Change direction (Control menu)
Bit12
Reserved
Bit13
Reserved
Bit14
Reserved
Bit15
Reserved
Standard interconnection
r8541
Speed setpoint from IOP
N_soll OP
Intelligent Operator Panel (IOP)
Operating Instructions, 08/2015, FW V1.6.1, A5E00110011B AF
Binector Inputs (BI)
->
->
->
->
->
->
->
->
->
->
->
->
->
->
->
->
Connector Inputs (CI)
->
5.1 Custom Hand mode
p8542
Effective STW1 in Custom Hand
mode
Bit0
ON/OFF1
Bit1
OFF2
Bit2
OFF3
Bit3
Inhibit/enable operation
Bit4
Ramp-function generator enable
Bit5
Continue ramp-function generator
Bit6
Setpoint enable
Bit7
Acknowledge faults
Bit8
Jog 1
Bit9
Jog 2
Bit10
Control by PLC
Bit11
Direction of rotating - reversed
Bit12
Speed control enable
Bit13
Motorized potentiometer, setpoint,
increase
Bit14
Motorized potentiometer, setpoint,
decrease
Bit15
CDS selection
p8543
Effective speed setpoint in Custom
Hand mode
Speed setpoint
Control