6.3

Adapt the default setting of the terminal strip

In the inverter, the input and output signals are interconnected with specific inverter functions
using special parameters. The following parameters are available to interconnect signals:
● Binectors BI and BO are parameters to interconnect binary signals.
● Connectors CI and CO are parameters to interconnect analog signals.
This chapter describes how you adapt the function of individual inverter inputs and outputs
using binectors and connectors.
Converter with the CU230P-2 Control Units
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257946B AE
Advanced commissioning
6.3 Adapt the default setting of the terminal strip
197