hit counter script

Post Error Messages - IBM totalstorage 326 User Reference

Network attached storage 300
Hide thumbs Also See for totalstorage 326:
Table of Contents

Advertisement

POST error messages

Table 27 provides information about the POST error messages that can appear
during startup.
Note that these diagnostic error messages require the attachment of a monitor,
keyboard, and mouse (before you power on the system) to enable you to see them.
In the following error messages, X can be any number or letter.
Table 27. POST error messages
Error
Meaning
code/Symptom
062
Three consecutive boot
failures using the default
configuration
101, 102
System and processor error
106
System and processor error
111
Channel check error
114
Adapter read-only memory
error
129
Internal cache error
151
Real-time clock error
161
Real-time clock battery error
162
Device Configuration error
163
Real-time clock error
164
Memory configuration
changed
175
Hardware error
140
Model 326 User's Reference
FRU/action
1. Run Configuration/Setup
2. Battery
3. System board
4. Processor
System board
System board
1. Failing ISA Adapter
2. DIMM
3. System board
1. Failing Adapter
2. Run Diagnostics
1. Processor
2. Optional processor (if installed)
1. Run Diagnostics
2. Battery
3. System board
1. Run Configuration/Setup
2. Battery
3. System board
1. Run Configuration/Setup
Note: Be sure to load the default settings and any
additional settings; then, save the configuration.
2. Battery
3. Failing Device
4. System board
1. Run Configuration/Setup
2. Battery
3. System board
1. Run Configuration/Setup
2. DIMM
System board

Advertisement

Table of Contents
loading

Table of Contents