iAquaLink™ Web Connect Device for AquaLink
People with infectious diseases should not use a spa or hot tub.
To avoid injury, exercise care when entering or exiting the spa or hot tub.
Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
Pregnant or possibly pregnant women should consult a physician before using a spa or hot tub.
Water temperature in excess of 100°F (38°C) may be injurious to your health.
Before entering a spa or hot tub, measure the water temperature with an accurate thermometer.
Do not use a spa or hot tub immediately following strenuous exercise.
Prolonged immersion in a spa or hot tub may be injurious to your health.
Do not permit any electric appliance (such as a light, telephone, radio, or television) within five (5) feet (1,52m) of a spa or hot
tub.
The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
Water temperature in excess of 100°F (38°C) may be hazardous to your health.
To avoid injury ensure that you use this control system to control only packaged pool/spa heaters which have built-in operating
and high limit controls to limit water temperature for pool/spa applications. This device should not be relied upon as a safety
limit control.
A terminal bar marked "GROUND" is provided within the power center. To reduce the risk of electrical shock which can cause
serious injury or death, connect this terminal bar to the grounding terminal of your electric service or supply panel with a
continuous copper conductor having green insulation and one that is equivalent in size to the circuit conductors supplying this
equipment, but no smaller than no. 12 AWG (3,3mm
(8,4mm
) copper wire to any metal ladders, water pipes, or other metal within five (5) feet (1,52 m) of the pool/spa. In Canada
2
the bonding wire must be minimum 6 AWG (13,3mm
A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The conductors
on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors
unless the additional conductors are also protected by a ground-fault circuit-interrupter. Refer to local codes for complete details.
Attention installer: Install to provide drainage of compartment for electrical components.
RS & PDA Control Systems
®
). In addition, a second wire connector should be bonded with a no. 8 AWG
2
).
2
SAVE THESE INSTRUCTIONS
|
Owner's Manual
WARNING
WARNING
WARNING
CAUTION
ENGLISH
Page 7