Page 6
Appareil A Laser de Classe 1 IEC 825-1:1993 CENELEC EN 60 825 Statement 4 ≥18 kg (37 lbs) ≥32 kg (70.5 lbs) ≥55 kg (121.2 lbs) CAUTION: Use safe practices when lifting. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 7
Statement 5 CAUTION: The power control button on the device and the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
Page 8
IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 10
Working with hot-swap cooling fans ....83 Working with hot-swap power supplies (dual-controller models only) ..84 viii IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 11
Removing a hot-swap power supply ....86 Installing a hot-swap power supply ....86 Working with hot-swap RAID controllers (dual-controller models only) .
Page 12
IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 14
74. Installing a new RAID controller ......97 IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 15
2. TotalStorage DS4500 Fibre Channel Storage Server document titles by user tasks ..xviii 3. TotalStorage DS4400 Fibre Channel Storage Server document titles by user tasks ..xix 4. TotalStorage DS4300 Fibre Channel Storage Server document titles by user tasks ..xx 5.
Page 16
IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
DS4300 Fibre Channel Storage Server. FAStT product renaming IBM is in the process of renaming some FAStT family products. Table 1 identifies each new DS4000 product name with its corresponding FAStT product name. Note that this change of product name only indicates no change in functionality or warranty.
DS4000 Storage Manager software installation process. Lined arrows in the flow chart indicate consecutive steps in the hardware and software installation process. Labeled arrows indicate which current documents provide detailed information about those steps. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Each table lists documents that are included in the libraries and what common tasks they address. You can access the documents listed in these tables at one of the following Web sites: www.ibm.com/servers/storage/support/disk/ www.ibm.com/shop/publications/order/ DS4500 storage server library Table 2 on page xviii associates each document in the DS4500 (previously FAStT900) storage server library with its related common user tasks.
DS4500 Installation and Support Guide, GC26-7727 IBM TotalStorage DS4500 Fibre Channel Cabling Instructions, GC26-7729 IBM TotalStorage DS4500 Storage Server User’s Guide, GC26-7726 IBM TotalStorage DS4500 Rack Mounting Instructions, GC26-7728 xviii IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
User Tasks Planning Hardware Software Configuration Operation and Diagnosis and Installation Installation Administration Maintenance IBM DS4400 Fibre Channel Storage Server User’s Guide, GC26-7730 IBM DS4400 Fibre Channel Storage Server Installation and Support Guide, GC26-7731 IBM DS4400 Fibre Channel Cabling Instructions,...
DS4300 storage server library Table 4 associates each document in the DS4300 (previously FAStT600) storage server library with its related common user tasks. Table 4. TotalStorage DS4300 Fibre Channel Storage Server document titles by user tasks Title User Tasks Planning...
Table 5. TotalStorage DS4100 SATA Storage Server document titles by user tasks Title User Tasks Planning Hardware Software Configuration Operation and Diagnosis and Installation Installation Administration Maintenance IBM TotalStorage DS4100 Installation, User’s and Maintenance Guide, GC26-7733 IBM TotalStorage DS4100 Cabling Guide, 24P8973 About this document...
AIX, UNIX, Solaris and Linux on POWER, GC26-7705 IBM TotalStorage DS4000 Storage Manager Version 9 Copy Services User’s Guide, GC26-7707 IBM TotalStorage DS4000 Storage Manager Version 9 Concepts Guide, GC26-7734 xxii IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
DS4000 Quick Start Guide, GC26-7738 IBM TotalStorage DS4000 Hardware Maintenance Manual,GC26-7702 IBM TotalStorage DS4000 Problem Determination Guide, GC26-7703 IBM Fibre Channel Planning and Integration: User’s Guide and Service Information, SC23-4329 IBM TotalStorage DS4000 FC2-133 Host Bus Adapter Installation and User’s Guide,...
Danger: These statements indicate situations that can be potentially lethal or extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation. xxiv IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This section contains information about where to go for additional...
For information about which products are supported by Support Line in your country or region, go to the following Web site: www.ibm.com/services/sl/products/ For more information about the IBM Support Line and other IBM services, go to the following Web sites: v www.ibm.com/services/ v www.ibm.com/planetwide/...
Fill out the Readers’ Comments form (RCF) at the back of this document and return it by mail or fax (1-800-426-6209) or give it to an IBM representative. If the RCF has been removed, you can address your comments to:...
Page 30
IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
IBM DS4300 Model 6LU/6LX Turbo Upgrade (IBM P/N 24P8964) Use this product to upgrade to the DS4300 Turbo option, which provides dual redundant RAID controllers and power supplies in addition to the following features: IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
RAID controllers with 1 GB of memory, instead of the standard 256-MB memory v Entitlements for IBM DS4000 Storage Manager and DS4300 controller firmware version 9.1. v Ability to connect up to seven DS4000 EXP storage expansion enclosures v Entitlement for eight partitions using the Storage Partitioning premium...
Page 34
IBM TotalStorage DS4000 Fibre Channel and Serial ATA Intermix Premium Feature Installation Overview that ships with the FC/SATA Enclosure Intermix premium feature. You can also refer to the IBM TotalStorage DS4000 Hard Drive and Storage Expansion Enclosure Installation and Migration Guide.
IBM TotalStorage DS4000 Fibre Channel and Serial ATA Intermix Premium Feature Installation Overview that ships with the FC/SATA Enclosure Intermix premium feature. You can also refer to the IBM TotalStorage DS4000 Hard Drive and Storage Expansion Enclosure Installation and Migration Guide. Features at a glance Table 9 summarizes the features of the storage server.
- White tape dots for marking the holes in the rack – Fibre Channel cabling instructions If an item is missing or damaged, contact your IBM reseller or your IBM marketing representative. If you have not already done so, record your storage server serial number in the table in Appendix A, “Records,”...
A storage system in an optimal state should recover automatically from an unexpected shutdown and unattended simultaneous restoration of power to system components. After power is restored, call IBM support if any of the following conditions occur: – The storage subsystem logical drives and arrays are not displayed in the Storage Manager graphical user interface (GUI).
Drive activity LED Tray handle Latch Drive fault LED Figure 2. Front controls and components Power-on LED When on, this green light indicates that the unit has good dc power. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
General-system-error LED When on, this amber LED indicates that the storage server has a fault, such as in a power supply, fan unit, or hard disk drive. Exception: Because a DS4300 single-controller storage server (Model 6LU/6LX) has only one power supply, this LED cannot light up when its power supply fails.
CRU is not operational. Hot-swap power supplies The storage server includes two hot-swap power supplies. Both power supplies must be installed to maintain proper cooling. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Exception: The DS4300 single-controller storage server (Model 6LU/6LX) has only one power supply. To maintain proper cooling, keep the cover on the second power supply bay. Interface ports and switches Figure 5 shows the ports and switches on the back of the DS4300 dual-controller storage server (Model 60U/60X).
Page 42
2 Gbps only. For controller firmware version 05.34.xx.xx and higher, the host ports can operate at either 1 or 2 Gbps (the expansion port speed is still locked at 2 Gbps only). IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Operating specifications Table 10 summarizes the operating specifications of the storage server. Table 10. DS4300 storage server operating specifications Environment Acoustical noise emissions values For Size (with front panel and without open bay (0 drives installed) and typical v Air temperature: mounting rails) system configurations (14 hard disk drives –...
Page 44
2440 mm between T42 racks center lines of hot and cold aisle back Hot aisle back T42 racks front Airflow Figure 7. Example of Cold Aisle/Hot Aisle Rack Configuration IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Rack-mounting hardware (comes with the storage server) v Storage-management software to configure the storage subsystems (comes with the storage server on the IBM TotalStorage DS4000 Storage Manager installation CD.) Rack mounting instructions and a template for aligning the holes in the rails and the rack come with the storage server.
Page 46
FRONT Rack Mounting Template Bezel Bezel Front Left Front Right Rail assembly Rail assembly Front Left Front Right Figure 8. Front rack mounting template IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 47
REAR Rack Mounting Template Rail assembly Rail assembly Rear Left Rear Right P/N 06P4631 Printed in the U.S.A. Figure 9. Rear rack mounting template Chapter 2. Installing and configuring the storage server...
1. To remove a RAID controller, push down on the latch centered on the controller; then, grasp the pull-rings on the levers and pull them to remove the RAID controller and set it aside for later installation. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
If you have a second RAID controller, repeat this step for the second controller. Caution: Observe ESD procedures when removing CRUs from the DS4300 storage server. See the storage server documentation for handling guidelines before removing any ESD-sensitive devices. Figure 10. RAID controller removal 2.
Page 50
5. Use the attached template and stickers to mark the appropriate holes on the rack; then install clip nuts or cage nuts as required for the rack cabinet. Note: Use the cage-nut-insertion tool or a flat-blade screwdriver to install cage nuts. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Cage Cage nuts Clip Clip nuts Cage Cage nuts Figure 14. Rack nut installation 6. On the rail marked R, remove the 6/32 in. screw 3 and loosen the four screws 2 ; then hold the front of the rail against the outside of the right rack-mounting-flange and loosely install two M6 screws 1 .
DS4300 on a Fibre Channel loop. The server ID switch is located on the back of the unit, as shown in Figure 18 on page 23. Note: The Server ID switch is sometimes referred to as an “Enclosure ID” switch. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Server ID Switch Figure 18. Setting the Server ID Server ID switch settings set the server ID to a value from 00 - 77. Server ID switch X1 is for setting the ones position, and Server ID switch X10 is for setting the tens position.
Fibre Channel I/O path Controller Note: The client software is installed on one or more Controller management systems, or on the host computer. Figure 19. Host-agent managed storage subsystems IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Direct-management method: This method uses Ethernet connections from a management station to each controller. You must install at least one management station. The management station can be the host or a workstation on the Ethernet network. A management station will have the client software installed. Attach Ethernet cables to each management station (one pair per storage server).
EXP700 attached (Figure 23 on page 28) v Two clusters (Figure 24 on page 29) Note: These configurations have host and drive path failover protection and are recommended for high availability. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Host system Host system Host system with two host with two host with two host adapters adapters adapters Note: Node level redundancy with cluster software. Switch Switch DS4300 DS4300 Host system Host system with two host with two host adapters adapters DS4300 Figure 21.
Host system with two host with two host adapters adapters Switch Switch DS4300 DS4300 DS4000 EXP700 (Storage expansion enclosure) Figure 23. Example of a dual-SAN fabric zone configuration (Model 60U/60X) IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Host system Host system Host system Host system with two host with two host with two host with two host adapters adapters adapters adapters Switch Switch Switch Switch DS4300 Figure 24. Example of a two-cluster configuration (Model 60U/60X) DS4300 single-controller storage server (Model 6LU/6LX) configurations: This section includes the following examples of DS4300 single-controller storage server (Model 6LU/6LX) configurations: v Single server configuration with one adapter (Figure 25)
Figure 26. Example of a single server configuration with two adapters (Model 6LU/6LX) Host Host Server Server DS4300 Single Controller Figure 27. Example of a dual-server configuration with one adapter on each server (Model 6LU/6LX) IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Host Host Server Server Switch DS4300 Single Controller Figure 28. Example of a dual-server, single-SAN fabric zone configuration with one adapter on each server (Model 6LU/6LX) Host Host Server Server Switch Switch DS4300 Single DS4300 Single Controller Controller Figure 29. Example of a dual-server, dual-SAN fabric zone configuration with two adapters per server (Model 6LU/6LX) Chapter 2.
Note: Do not install the storage-management software at this time, if it is not already installed. Install the storage server completely before you install the software because you cannot test the software installation until the hardware is connected. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Storage Manager client to view the Storage Subsystem Profile in order to verify that you are not mixing long-wave and short-wave SFPs. To install an SFP module, complete the following steps. Statement 3: IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber-optic devices, or transmitters) are installed, note the following: v Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.
Figure 32. Unlocking the SFP module latch - plastic variety v For SFP modules containing wire tabs, unlock the SFP module latch by pulling the wire latch outward 90°, as shown in Figure 33 on page 37. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Wire Protective module Figure 33. Unlocking the SFP module latch - wire variety 3. With the SFP latch in the unlocked position, extract the SFP module. v For SFP modules containing plastic tabs, slide the SFP module out of the port.
2. Connect the host-system Fibre Channel cables between the RAID controller host ports and the HBA ports or Fibre Channel switch ports. Figure 36 on page 39 shows the location on the RAID controllers where the host-system cables connect. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Controller A Controller B Host A: Host Adapter 1 Host A: Host Adapter 2 (or from managed hub (or from managed hub or switch) or switch) Figure 36. Location of host cables (Model 60U/60X) For examples of redundant, partially redundant, and nonredundant host and drive loop configurations, see “Fibre Channel loop configurations”...
If you have not already done so, attach the power cords, using the following illustration for the location of the component parts. Lever AC power Strain-relief AC power connector clamp switch Figure 39. Power cord locations IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 71
Complete the following steps to attach the power cords. 1. Wrap the strain-relief clamp around the power cord approximately 20 cm (8 in.) from the power supply connection end. 2. Attach the power-supply nut, and tighten it securely. 3. Connect the power cord to the power supply. 4.
To connect an additional storage expansion enclosure, perform the following steps. Note: The following procedure is for ″cold-case″ (the DS4300 storage server is powered down when storage expansion enclosures are connected. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 73
1. Follow the instructions in your storage expansion enclosure installation manual to set up and mount the new storage expansion enclosure. 2. Use the following procedure and Figure 41 to connect a single storage expansion enclosure to the storage server: a.
Page 74
For additional information about how to cable the storage server and storage expansion enclosures, see the DS4300 Fibre Channel Cabling Instructions that come with the storage server. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
A storage system in an optimal state should recover automatically from an unexpected shutdown and unattended simultaneous restoration of power to system components. After power is restored, call IBM support if any of the following conditions occur: –...
4. Use the storage-management software and the Fault LEDs to check the overall status of the storage server and its components. All LEDs should be green on IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
the front of the storage server. If they are not, use the storage-management software to diagnose the problem (see “Monitoring status through software” on page 50). Note: The green Drive active LED and amber Drive fault LED below the drive CRUs might flash intermittently as the drives spin-up.
(listed in “Turning off the storage server” on page 47) because of an emergency situation. Attention: To avoid damage to the hardware, take special care when restarting the system after an unexpected shutdown. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
If the storage server shuts down unexpectedly, go to “Restoring power after an over-temperature shutdown.” Otherwise, go to “Restoring power after an emergency shutdown.” Note: Unattended restoration of power is supported; however, if power restoration is attended, you should follow the best practices guidelines and the power restoration sequence in “Turning on the storage server”...
(such as backing up the logical drive or failing a drive before removing it). The storage-management software gives these procedures. Attention: Not following the software-recovery procedures can result in data loss. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
NVSRAM (for controllers only) must be up to date. Go to the following Web site to get the latest updates. http://www-1.ibm.com/servers/storage/support/disk/ Apply the necessary updates before configuring the DS4300 arrays and logical drives. Subscribe to My Support for automatic notifications of firmware or storage manager software updates or any important information about your DS4000 subsystems (see “Product updates”...
Not all component failures turn on this LED. For more information, see “Monitoring status through software” on page 50. Figure 44 on page 53 shows the locations of the LEDs on the DS4300 storage server. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Exception: The DS4300 single-controller storage server (models 6LU/6LX) does not have the expansion port and the expansion port bypass LED. Expansion link indicator 2Gbps Expansion Host 1 Host 2 10101 10BT 100BT 2Gb/s 2Gb/s Host 2 Expansion Host 1 Battery Cache Controller 10BT...
Always use the storage-management software to identify the failure. Fan fault LED Power supply Fan fault LED Power LED Power LED fault LEDs Figure 45. Fan and power supply LEDs IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Table 13. Fan LED Color Operating states Fault Amber v Off - Normal operation. v On - The fan CRU has failed. Always use the storage-management software to identify the failure. Table 14. Power supply LEDs Color Operating states Fault Amber v Off - Normal operation.
Data caching starts after the battery completes the startup tests. Figure 47 on page 57 shows the location of the Battery LED on the front of the RAID controller. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
IBM DS4300 Model 6LU/6LX Upgrade, IBM part number 24P8963 v IBM DS4300 Model 6LU/6LX Turbo Upgrade, IBM part number 24P8964 See “DS4300 Model 6LU/6LX” on page 2 for a description of the differences between the two upgrade kits.
For example, Microsoft MSCS periodically writes to the Quorum disk. 4. Stop I/O to the storage server. 5. Unmount any mapped LUNs from the storage server. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 91
® Note: In a Microsoft Windows environment, remove the drive letter or the mount points of the mapped LUNs instead of unmounting the file systems. 6. If applicable, remove the controller WWNN from the Fibre Channel switch fabric zone definitions or any applications that use this WWNN info. 7.
Page 92
Remove it, and then reinstall it. Ensure that the electrical outlet is hot. v If the Fault LED is on, or if the Power LED stays off, contact your IBM support representative. Note: To maintain power redundancy on the DS4300 dual-controller storage...
DS4300 that will be upgraded before you replace the old controller with the new controller. For more information, see IBM DS4000 Storage Manager Installation and Support Guide for your operating system, or the following Web site: www-1.ibm.com/servers/storage/support/disk/...
You must replace both controllers. Replace one controller at a time. To upgrade your RAID controller, complete the following steps: 1. Open a management connection to the DS4300 using the Storage Manager client. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 95
2. Save the storage server profile to a disk location that is not in the DS4000 storage server that you are upgrading. In the Subsystem Management window, select View-->Storage Subsystem Profile. When the Storage Subsystem Profile window opens, click Save As. The Save Profile window opens. Select an appropriate directory and choose a file name for the profile, then click Save.
Figure 50. Unlocking the SFP module latch - plastic variety v For SFP modules that contain wire tabs, unlock the SFP module latch by pulling the wire latch outward 90°, as shown in Figure 51 on page 67. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Wire Protective module Figure 51. Unlocking the SFP module latch - wire variety c. With the SFP latch in the unlocked position, extract the SFP module. v For SFP modules that contain plastic tabs, slide the SFP module out of the port.
Page 98
19. Enable controller caching by completing the following steps: IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Subsystem Management window. 20. Verify firmware and NVSRAM. Reload the firmware and NVSRAM to the version shipped on the Turbo option CD. Then, check the IBM Web site for any firmware updates. Steps for cold-swap RAID controller upgrade...
Click Select All to select all logical drives, and deselect all of the Cache Setting Enable check boxes, then click OK. Click OK when the Confirmation window opens. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Note: A progress window shows the modification progress. After the cache setting modification complete, click OK to close the progress window and return to the Subsystem Management window. Refer to the Storage Manager client online Help panels for more details on disabling cache.
Grasp the pull-rings (see Figure 57 on page 73), then pull on the levers and remove the RAID controller. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Figure 57. Pull-rings for removing a controller 12. Unpack the new RAID controller with the 1-GB cache. Verify that the battery is in the controller by opening the DS4300 controller CRU, using step 6 through step 9 of “Replacing the battery in the RAID controller” on page 94. If there is no battery in the new DS4300 controller, remove the battery from the old controller and install it in the new controller.
22. Enable caching on both controllers. 23. Verify firmware and NVSRAM. Reload the firmware and NVSRAM to the version shipped on the Turbo option CD. Then, check the IBM Web site for any firmware updates. 24. If applicable, re-enable your premium features using the premium features key files of the controllers that you replaced.
Filler panels Storage servers without a full set of drives (14) contain filler panels in the unused drive bays. Before installing new drives, you must remove the filler panels. Save the filler panels for future use. Each of the 14 bays must always contain either a filler panel or a drive CRU.
Page 106
10 seconds; then reinstall the drive. 6. Use the Storage Manager client to configure the drive. 7. Update the information in Appendix A, “Records,” on page 105. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Replacing hot-swap drives Drive problems include any malfunctions that delay, interrupt, or prevent successful I/O activity between the hosts and the hard disk drives. This includes transmission problems between the host controllers, the RAID controllers, and the drives. This section explains how to replace a failed drive. Attention: 1.
Instructions that are provided with your software should supersede anything stated in this document. There are two methods for upgrading drives: v Replacing all the drives at the same time IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
This method requires that you back up the data on the affected drives and then turn off the storage server. After replacing all the drives, you must reconfigure the new drives and restore data from backup. See the procedure in “Replacing all drives at the same time.”...
Page 110
8. After you install all the new drives, check the system documentation for the hardware devices that you intend to power up, and then determine the proper startup sequence. Use the following power-on sequence, where applicable: IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
a. Turn on the power to the supporting devices (for example, Ethernet switches and management stations) before you turn off power to the storage server. b. You must turn on the storage expansion enclosures before the storage server. The controllers might not recognize the correct configuration if the drives are powered up after the storage server.
Page 112
Note: The Drive fault LEDs might flash intermittently while the drives spin up. v If the Drive activity LED is off, the drive CRU might not be installed correctly. Remove the drive CRU, wait 30 seconds, and then reinstall it. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
v If the Drive fault LED stays on or the Drive activity LED stays off, the new drive might be faulty. See the Storage Manager client for problem determination. 8. Use the Storage Manager client to monitor the status of the new drive and the progress of the data reconstruction.
One power supply CRU can maintain electrical power to the unit if the other power supply is turned off or malfunctions. The power supply CRUs are interchangeable (by reversing the locking levers). IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 115
Each power supply CRU has a built-in sensor that detects the following conditions: v Over-voltage v Over-current v Overheated power supply If any of these conditions occurs, one or both power supplies will shut down. All power remains off until you cycle the power switches (turn the power switches off, wait at least 30 seconds, then turn the power switches on).
Installing a hot-swap power supply Note: When you replace a power supply that has failed, ensure that the power supply latch is mounted on the side of the power supply that faces the IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
middle of the storage server. If it is not, remove the lever screw, flip the lever over, and tighten the screw on the opposite side. Figure 65. Installing a hot-swap power supply To install a hot-swap power supply, perform the following steps: Statement 8 CAUTION: Never remove the cover on a power supply or any part that has the following label...
Controller FRU part number (P/N) Single-controller (Model 6LU/6LX) 24P8961 Dual-controller, standard (Model 60U/60X) 24P8059 Dual-controller, Turbo option with 1-GB cache 24P8225 (Model 60U/60X) Important: Please note the following information. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
v The cache battery is not included with the controller FRU. v Ensure that you replace the failed controller with the appropriate FRU. There are no protection mechanisms to block out an incorrect FRU from being inserted into DS4300 controller slots. Unpredictable results can occur when nonmatching controller FRUs are present in a single DS4300 chassis.
Figure 69. Unlocking the SFP module latch - plastic variety v For SFP modules that contain wire tabs, unlock the SFP module latch by pulling the wire latch outward 90°, as shown in Figure 33 on page 37. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Wire Protective module Figure 70. Unlocking the SFP module latch - wire variety c. With the SFP latch in the unlocked position, extract the SFP module. v For SFP modules that contain plastic tabs, slide the SFP module out of the port.
Page 122
12. Place the replacement RAID controller CRU bottom up on a flat surface. Using a #2 Phillips head screwdriver, remove the six screws (three on each side of IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 123
If the Fault LED is on, the Host Loop LED and the Expansion Loop LED stay off, or any other Fault LED is on, see the Storage Manager client for problem determination, or contact IBM support. Chapter 5. Installing and replacing components...
When you handle static-sensitive devices, take precautions to avoid damage from static electricity. For details about handling static-sensitive devices, see “Handling static-sensitive devices” on page 59. 2. Unpack the new battery. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 125
Set the new battery on a dry, level surface. Save all packing materials in case you need to return the battery. Note: The battery comes with a new battery label. You will need this label later in the procedure. 3. Review all documentation that comes with the new battery for updated replacement procedures and other information.
Page 126
This product contains a sealed lead acid battery. The battery must be recycled or disposed of properly. In the United States, IBM has established a collection process for reuse, recycling, or proper disposal of used IBM sealed lead acid batteries.
Figure 74. Installing a new RAID controller a. Slide the RAID controller all the way into the empty slot. b. Close both levers until the latch locks into place. 21. Install the SFPs and then connect the fibre-channel cables to their original locations.
Page 128
IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
For instructions on how to obtain service and technical assistance for your storage server and other IBM products, see “Getting information, help, and service” on page Note: See the IBM TotalStorage DS4000 Hardware Maintenance Manual and Problem Determination Guide for additional troubleshooting and debugging procedures.
Manager software to diagnose server problems. Amber LED is off Power-supply Power switch is Turn on all power-supply power and green LED off turned off or ac switches. power failure IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 131
Table 15. Storage server troubleshooting (continued) Problem indicator Component Possible cause Possible solutions Amber and green Power-supply Power supply Replace the failed power-supply LEDs on failure CRU. All green LEDs off All CRUs Subsystem power Check that all storage-server is off power cords are plugged in and the power switches are on.
Page 132
SFP has failed Ensure SFP is seated properly; replace SFP. RAID controller Ensure that the unit is powered has no power or on. Replace RAID controller. has failed IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 133
Table 15. Storage server troubleshooting (continued) Problem indicator Component Possible cause Possible solutions One or more Expansion loop Drives are Ensure that the drives are green LEDs off improperly properly installed. (continued) installed or not installed RAID controller Ensure that the unit is powered has no power or on.
Page 134
IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 138
Move keyboard focus down one item in the list. Left arrow Move keyboard focus to the left. Right arrow Move keyboard focus to the right. Up arrow Move keyboard focus up one item in the list. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
Japanese Voluntary Control Council for Interference (VCCI) statement Power cords For your safety, IBM provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.
Page 143
The cord set should have the appropriate safety approvals for the country in which the equipment will be installed. IBM power cords for a specific country or region are usually available only in that country or region.
Page 144
IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
TotalStorage DS4000 publications. advanced technology (AT) bus architecture. A bus standard for IBM compatibles. It extends the XT bus If you do not find the term you are looking for, see architecture to 16 bits and also allows for bus...
Page 146
SCSI targets logically connected to an FC adapter. CRT. See cathode ray tube. DRAM. See dynamic random access memory. CRU. See customer replaceable unit. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 147
(CRU). Extended Industry Standard Architecture (EISA). A FlashCopy. A premium feature for DS4000 that can bus standard for IBM compatibles that extends the make an instantaneous copy of the data in a volume. Industry Standard Architecture (ISA) bus architecture to 32 bits and allows more than one central processing F_port.
Page 148
An entity in the storage partition topology and the physical network. that defines a logical collection of host computers that require shared access to one or more logical drives. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 149
Internet Protocol (IP) address. The unique 32-bit loop address. The unique ID of a node in address that specifies the location of each device or fibre-channel loop topology sometimes referred to as a workstation on the Internet. For example, 9.67.97.103 is loop ID.
Page 150
Object Data Manager (ODM). An AIX proprietary identifier of the storage subsystem for which the storage mechanism for ASCII stanza files that are edited as part of configuring a drive into the kernel. IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 151
(PTF). A temporary solution or bypass of a problem diagnosed by IBM in a current RVSD. See recoverable virtual shared disk. unaltered release of the program.
Page 152
(SAN). A dedicated storage synchronous write mode. In remote mirroring, an network tailored to a specific environment, combining option that requires the primary controller to wait for the IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 153
acknowledgment of a write operation from the uninterruptible power supply. A source of power secondary controller before returning a write I/O request from a battery that is installed between a computer completion to the host. See also asynchronous write system and its power source. The uninterruptible power mode, remote mirroring, Metro Mirroring.
Page 154
IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 156
5 cache battery 56 fiber-optic cable fan 55 handling 33 hard disk drive 52 installing 37 power supply 55 removing 38 RAID controller 53 working with 33 IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 157
LEDs (continued) notices (continued) storage server 52 FCC, Class A 110 troubleshooting 100 safety information iii lever on power supply, changing location 87 static-sensitive precautions 59 loop configurations used in this book xxiv overview 26 redundant 26 online help xvi operating specifications of storage server 13 managed hub over-temperature condition, shutdown 49...
Page 158
18 installing SFP modules 34 interface ports and switches 11 inventory checklist 6 LEDs 51, 52, 53, 55 mounting in a rack 15 operating specifications 13 IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 160
IBM TotalStorage DS4300 Fibre Channel Storage Server: Installation and User’s Guide...
Page 161
Thank you for your responses. May we contact you? h Yes h No When you send comments to IBM, you grant IBM a nonexclusive right to use or distribute your comments in any way it believes appropriate without incurring any obligation to you. Name...
Page 162
Readers’ Comments — We’d Like to Hear from You Cut or Fold Along Line GC26-7722-01 Fold and Tape Please do not staple Fold and Tape _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ NO POSTAGE NECESSARY IF MAILED IN THE...
Page 164
Part Number: 39M5579 Printed in USA GC26-7722-01...