3.18 Log Utilities
This function logs error information generated while a test is in progress and stores the
results in RAM (Maximum error log : 500 times). This function can store data on a floppy
disk. If the power switch is turned off, the error information will be lost. Error information is
displayed in the following order:
1. Error count (CNT)
2. Test name and subtest number (TEST)
3. Pass count (PASS)
4. Error status (STS)
5. FDD/HDD or memory address (ADDR)
6. Write data (WD)
7. Read data (RD)
8. Error Name ( ERROR NAME/DETAILS)
3.18.1 Operations
1. Select 04 and press Enter in the Diagnostics Menu to log error information into
RAM or onto a floppy disk. Error information is displayed in the following format:
XXXX ERRORS
CNT
TEST
PASS
001
FDD 02
0000
002
FDD 01
0000
Pass Count
Subtest Number
Test Name
Error Count
[[1:Next, 2:Prev, 3:Exit, 4;Clear, 5:FD Log Read, 6:FD Log Write, 7:Log Save]]
Satellite L600/L640/L645, Satellite Pro L600/Pro L640/Pro L645 Maintenance Manual (960-Q08)
PASSCOUNT = XXXX
STS
ADDR
WD
180
0000001
00
120
0000001
00
Address
Error Status
Write Data
Test Program for Field.
RD
ERROR NAME/DETAILS
00
WRITE PROTECTED
00
TIME OUT ERROR
Read Data
Error Name and Detail